Genotyping of methicillin-resistant Staphylococcus aureus isolates obtained in the Northeast region of Brazil
Methicillin-resistant Staphylococcus aureus (MRSA) is a major agent of hospital infections worldwide. In Brazil, a multiresistant MRSA lineage (ST239-SCCmecIIIA), the so-called Brazilian epidemic clone (BEC), has predominated in all regions. However, an increase in nosocomial infections caused by non-multiresistant MRSA clones has recently been observed. In the present study, 45 clinical isolates of MRSA obtained from a university hospital located in Natal city, Brazil, were identified by standard laboratory methods and molecularly characterized using staphylococcal chromosome cassette mec (SCCmec) typing and pulsed-field gel electrophoresis. Antimicrobial susceptibility testing was carried out using CLSI methods. The MRSA isolates studied displayed a total of 8 different pulsed-field gel electrophoresis patterns (types A to H) with predominance (73%) of pattern A (BEC-related). However, MRSA harboring SCCmec type IV were also identified, 3 (7%) of which were genetically related to the pediatric clone - USA800 (ST5-SCCmecIV). In addition, we found a considerable genetic diversity within BEC isolates. MRSA displaying SCCmecIV are frequently susceptible to the majority of non-β-lactam antibiotics. However, emergence of multiresistant variants of USA800 was detected.
Main Authors: | , , , , , , , |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
Associação Brasileira de Divulgação Científica
2009
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2009001000002 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Methicillin-resistant Staphylococcus aureus (MRSA) is a major agent of hospital infections worldwide. In Brazil, a multiresistant MRSA lineage (ST239-SCCmecIIIA), the so-called Brazilian epidemic clone (BEC), has predominated in all regions. However, an increase in nosocomial infections caused by non-multiresistant MRSA clones has recently been observed. In the present study, 45 clinical isolates of MRSA obtained from a university hospital located in Natal city, Brazil, were identified by standard laboratory methods and molecularly characterized using staphylococcal chromosome cassette mec (SCCmec) typing and pulsed-field gel electrophoresis. Antimicrobial susceptibility testing was carried out using CLSI methods. The MRSA isolates studied displayed a total of 8 different pulsed-field gel electrophoresis patterns (types A to H) with predominance (73%) of pattern A (BEC-related). However, MRSA harboring SCCmec type IV were also identified, 3 (7%) of which were genetically related to the pediatric clone - USA800 (ST5-SCCmecIV). In addition, we found a considerable genetic diversity within BEC isolates. MRSA displaying SCCmecIV are frequently susceptible to the majority of non-β-lactam antibiotics. However, emergence of multiresistant variants of USA800 was detected. |
---|