Measurement of retina/choroid complex perfusion with magnetic resonance imaging in eyes with acute primary angle-closure

ABSTRACT Purpose: To measure retina/choroid complex perfusion with magnetic resonance imaging in eyes with acute primary angle-closure (APAC). Methods: Three sequences of magnetic resonance imaging, two anatomical and one perfusional using gadolinium, were acquired in patients who were diagnosed with acute primary angle-closure. Regions of interest were drawn on the perfusional sequence and overlaid to the anatomical sequence. The relative blood volume measured during the first 2 s was considered as the baseline value and the change during the subsequent 28 s was analyzed. Results: Five eyes of 5 patients with acute primary angle-closure were included (3 with unilateral and 2 with bilateral acute primary angle-closure). Three contralateral eyes and 2 eyes of 2 healthy patients, paired for age and sex, were included in the control group. Acute primary angle-closure patients included 4 (80%) women, with an average age of 65.8 ± 12.37 y, mean intraocular pressure of 56.2 ± 14.67 mmHg, mean arterial pressure of 113.4 ± 8.17 mmHg, and average ocular perfusion pressure of 57.2 ± 13.46 mmHg. In the control group, the mean intraocular pressure was 15.6 ± 2.61 mmHg (p=0.0625), the mean arterial pressure was 107.4 ± 6.57 mmHg (p=1.00), and the average ocular perfusion pressure was 91.8 ± 6.72 mmHg (p=0.0625). The relative blood volume of the retina/choroid complex was -0.127 ± 0.048 in acute primary angle-closure patients and -0.213 ± 0.116 in the controls (p=0.3125). Conclusion: The magnetic resonance imaging sequence with gadolinium did not show a change in the retina/choroid complex perfusion in the eyes of patients with acute primary angle-closure.

Saved in:
Bibliographic Details
Main Authors: Ayub,Gabriel, Campos,Brunno M., Rezende,Thiago J. R., Cendes,Fernando, Vasconcelos,José Paulo Cabral de, Costa,Vital Paulino
Format: Digital revista
Language:English
Published: Conselho Brasileiro de Oftalmologia 2022
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492022000200166
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:ABSTRACT Purpose: To measure retina/choroid complex perfusion with magnetic resonance imaging in eyes with acute primary angle-closure (APAC). Methods: Three sequences of magnetic resonance imaging, two anatomical and one perfusional using gadolinium, were acquired in patients who were diagnosed with acute primary angle-closure. Regions of interest were drawn on the perfusional sequence and overlaid to the anatomical sequence. The relative blood volume measured during the first 2 s was considered as the baseline value and the change during the subsequent 28 s was analyzed. Results: Five eyes of 5 patients with acute primary angle-closure were included (3 with unilateral and 2 with bilateral acute primary angle-closure). Three contralateral eyes and 2 eyes of 2 healthy patients, paired for age and sex, were included in the control group. Acute primary angle-closure patients included 4 (80%) women, with an average age of 65.8 ± 12.37 y, mean intraocular pressure of 56.2 ± 14.67 mmHg, mean arterial pressure of 113.4 ± 8.17 mmHg, and average ocular perfusion pressure of 57.2 ± 13.46 mmHg. In the control group, the mean intraocular pressure was 15.6 ± 2.61 mmHg (p=0.0625), the mean arterial pressure was 107.4 ± 6.57 mmHg (p=1.00), and the average ocular perfusion pressure was 91.8 ± 6.72 mmHg (p=0.0625). The relative blood volume of the retina/choroid complex was -0.127 ± 0.048 in acute primary angle-closure patients and -0.213 ± 0.116 in the controls (p=0.3125). Conclusion: The magnetic resonance imaging sequence with gadolinium did not show a change in the retina/choroid complex perfusion in the eyes of patients with acute primary angle-closure.