Stepped spillways with aerators: hydrodynamic pressures and air entrainment

ABSTRACT The possibility of damage due to the phenomenon of cavitation leads the design of stepped spillways considering maximum specific discharges of 15 to 30 m2/s, a limit considerably lower than that practiced on smooth chutes. Aerators promote the insertion of air in the flow, allowing for the increase of specific flow rates. This work analyzes the pressures on the vertical faces of the steps and the air entrainment coefficient in the flow, through an experimental study in a physical model with a stepped chute angle of 53.13o, considering the installation of aerators in different places of the channel. Comparing the tested conditions with the natural aeration, it is concluded that the installation of the aerator does not change the magnitude of the minimum extreme hydrodynamic pressures, but anticipates the beginning of the flow aeration. A new equation is proposed to estimate the air entrainment coefficient, as well as a methodology for forecasting extreme pressures on the vertical faces of the steps, both valid in the range 3.0 ≤ Fr ≤ 6.0.

Saved in:
Bibliographic Details
Main Authors: Ferla,Rute, Novakoski,Carolina Kuhn, Priebe,Priscila dos Santos, Prá,Mauricio Dai, Marques,Marcelo Giulian, Teixeira,Eder Daniel
Format: Digital revista
Language:English
Published: Associação Brasileira de Recursos Hídricos 2021
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2318-03312021000100203
Tags: Add Tag
No Tags, Be the first to tag this record!