HPLC method development for the simultaneous analysis of amlodipine and valsartan in combined dosage forms and in vitro dissolution studies

A simple, rapid and reproducible HPLC method was developed for the simultaneous determination of amlodipine and valsartan in their combined dosage forms, and for drug dissolution studies. A C18 column (ODS 2, 10 μm, 200 x 4.6 mm) and a mobile phase of phosphate buffer (pH 3.6 , 0.01 mol L-1):acetonitrile: methanol (46:44:10 v/v/v) mixture were used for separation and quantification. Analyses were run at a flow-rate of 1 mL min-1 and at ambient temperature. The injection volume was 20 μL and the ultraviolet detector was set at 240 nm. Under these conditions, amlodipine and valsartan were eluted at 7.1 min and 3.4 min, respectively. Total run time was shorter than 9 min. The developed method was validated according to the literature and found to be linear within the range 0.1 - 50 μg mL-1 for amlodipine, and 0.05 - 50 μg mL-1 for valsartan. The developed method was applied successfully for quality control assay of amlodipine and valsartan in their combination drug product and in vitro dissolution studies.

Saved in:
Bibliographic Details
Main Authors: Çelebier,Mustafa, Kaynak,Mustafa Sinan, Altınöz,Sacide, Sahin,Selma
Format: Digital revista
Language:English
Published: Universidade de São Paulo, Faculdade de Ciências Farmacêuticas 2010
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1984-82502010000400018
Tags: Add Tag
No Tags, Be the first to tag this record!