Experimental analysis of reinforced concrete columns strengthened with self-compacting concrete and connectors

There are many problems involving cases of destruction of buildings and other structures. The columns can deteriorate for several reasons such as the evolution and changing habits of the loads. The experimental phase of this work was based on a test involving nine reinforced concrete columns under combined bending and axial compression, at an initial eccentricity of 60 mm. Two columns were used as reference, one having the original dimensions of the column and the other, monolithic, had been cast along the thickness of the strengthened piece. The remaining columns received a 35 mm thick layer of self-compacting concrete on their compressed face. For the preparation of the interface between the two materials, this surface was scarified and furrowed and connectors were inserted onto the columns' shear reinforcement in various positions and amounts.As connectors, 5 mm diameter steel bars were used (the same as for stirrups), bent in the shape of a "C" with 25 mm coatings. >As a conclusion, not only the quantity, but mainly, the location of the connectors used in the link between substrate and reinforcement is crucial to increase strength and to change failure mode.

Saved in:
Bibliographic Details
Main Authors: Nascimento,P. P., Gomes,R. B., Borges,L. L. J., David,D. L.
Format: Digital revista
Language:English
Published: IBRACON - Instituto Brasileiro do Concreto 2012
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952012000300004
Tags: Add Tag
No Tags, Be the first to tag this record!