Mechanical analysis of femoral neck fracture fixation with dynamic condylar screw in synthetic bone

Objective: To analyze statistically results in biomechanical testing of fixation of femoral neck Pauwels type III fractures, on synthetic bone, with dynamic condylar screw (DCS) and control group.Methods: Ten synthetic bones of a national brand were used. Test Group: fixation was performed after osteotomy at 70o tilt using DCS plate with four holes. We analyzed the resistance of this fixation with 5 mm displacement and rotational deviation (Step 1) and with10 mm (Step 2). Control group: the models were tested in their integrity until the femoral neck fracture occurred.Results: The values of the test group in Step 1 showed a mean of 974N and SD = 114N. In Stage 2, we obtained on average 1335N and SD = 98N. The values in the control group were: 1544N, 1110N, 1359N, 1194N, 1437N, respectively. Statistical analysis using the Mann-Whitney test for comparison of the maximum force (N) between the test group and the control, in Step 2, demonstrated that there is no significant difference between the DCS and control plates (p = 0.91).Conclusion: There is no significant difference between the DCS boards and the control group exposed to full resistance. Level of Evidence III, Case Control.

Saved in:
Bibliographic Details
Main Authors: Freitas,Anderson, Maciel,Rafael Almeida, Lima,Renato De Almeida, Souto,Diogo Ranier De Macedo, Ferrer,Marcelo De Almeida
Format: Digital revista
Language:English
Published: ATHA EDITORA 2014
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-78522014000500264
Tags: Add Tag
No Tags, Be the first to tag this record!