Evaluation of the use of PetrifilmTM EB count plates for the enumeration of Enterobacteriaceae in poultry samples

A test that is rapid, simple, accurate, not expensive, gives rapid results, and is sensitive enough to detect low levels of microorganisms would be the most suitable for food industry routine laboratories, or even for a public health laboratories. A ready-to-use alternative, commercially available method is the PetrifilmTM EB method. The aim of this study was to evaluate whether there is a statistically significant difference between the conventional methods based on Violet Red Bile Glucose Agar and the alternative 3M TM Petrifilm (EB) method for the enumeration of Enterobacteriaceae in poultry carcasses. This study also assessed whether the alternative method showed ability to produce results that were directly proportional to the concentration of the target (approximately 270 colony-forming unit.mL-1). A total of 120 poultry carcasses samples showed a significant difference (p < 0.05) between the populations obtained by the two methods, and the conventional method showed low proportionality between the dilutions. On the other hand, the PetrifilmTM EB quantification system showed the capacity to produce results that are proportional to the concentration of the analyte in samples in the concentration range from 1 to 256 colony-forming unit.mL-1.

Saved in:
Bibliographic Details
Main Authors: Drebes,Tainá, Majolo,Cláudia, Fröder,Hans
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Ciência e Tecnologia de Alimentos 2012
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0101-20612012000300024
Tags: Add Tag
No Tags, Be the first to tag this record!