Dissolution test for glibenclamide tablets

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Saved in:
Bibliographic Details
Main Authors: Gianotto,Elisabeth Aparecida dos Santos, Arantes,Renata Pires, Lara-Filho,Maurilio José, Casimiro Filho,Alexandre Cezar Saraiva, Fregonezi-Nery,Marlene Maria
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Química 2007
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422007000500031