Incidence of hemorrhagic complications with use of a radial compression device: a cohort study

ABSTRACT Objective: To examine the incidence of hemorrhagic complications in patients undergoing radial cardiac catheterization and using a hemostatic device for arterial compression. Method: A prospective cohort study conducted with patients undergoing elective cardiac catheterization in two hemodynamic laboratories in southern Brazil. The TR Band® radial compression device was used during 4 hours for hemostasis of the arterial puncture site. Hematomas and minor bleeding were the outcomes evaluated. Results: A total of 244 patients were evaluated. The mean age was 63.5±10.9 years, 61.9% were male, 73.8% had systemic arterial hypertension (SAH) and 42.8% were dyslipidemic. Type I hematoma occurred in 1.2% of patients and minor bleeding in 9% after removal of the device. There was no significant association between hematomas and bleeding, and patients who used oral anticoagulants (p=0.604) and prior use of antiplatelets (p=0.958). Conclusion: The use of the hemostatic device for radial artery compression was safe in clinical practice and there was a low incidence of hematomas and minor bleeding after radial coronary angiography.

Saved in:
Bibliographic Details
Main Authors: Córdova,Eliane Silva Machado, Santos,Lidiane Rodrigues dos, Toebe,Daiane, Moraes,Maria Antonieta Pereira de, Souza,Emiliane Nogueira de
Format: Digital revista
Language:English
Published: Universidade de São Paulo, Escola de Enfermagem 2018
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0080-62342018000100484
Tags: Add Tag
No Tags, Be the first to tag this record!