Calibration of two capacitive soil moisture sensors in Ultisol

Abstract The objectives of this study were to perform the calibration and determine the calibration equations of two ECH2O soil moisture sensors, for an Ultisol, collected in the Municipality of Pesqueira-PE located in Brazilian semi-arid region. The study was carried out in 5-liter plastic containers in a protected environment at the Federal Rural University of Pernambuco, Recife-PE, where soil moisture was daily monitored for 51 days from saturation moisture to natural drying. The authors verified that the ECH2O sensors showed an exponential response to the variation of soil moisture, obtaining R2>0.97. RMSE values ranged from 0.065 to 0.012 m3 m-3 for the 5TE sensor and from 0.045 to 0.011 m3 m-3 for the EC-5 sensor. The researchers concluded that the calibration equations obtained were more accurate than the factory equations for that type of soil.

Saved in:
Bibliographic Details
Main Authors: de los Ángeles Calva Jiménez,Anabel, Duarte Guedes Cabral de Almeida,Ceres, Santos Júnior,José Amilton dos, Silva dos Santos,Célia
Format: Digital revista
Language:English
Published: Universidad Nacional de Colombia 2020
Online Access:http://www.scielo.org.co/scielo.php?script=sci_arttext&pid=S0012-73532020000200075
Tags: Add Tag
No Tags, Be the first to tag this record!