Data from: Sorption and desorption of bicyclopyrone on soils

[Methods] Bicyclopyrone sorption was determined on each soil in triplicate using the batch equilibration method with radiolabeled compounds. The 14C spiking solution for BCP was prepared by diluting 14C-bicyclopyrone [pyridinyl-3-14C; specific activity = 95.3 µCi mg-1; 8,880 Bq mmol-1; 99.5% purity] with unlabeled BCP (Syngenta Crop Protection, LLC) to result in a stock solution of 10 mg L−1 with an overall activity of 1,090 Bq mL-1 (65,450 DPM mL-1). A 0.5 mL aliquot of this spiking solution was added to 9.5 mL of 0.01 M CaCl2 to achieve a 10 mL solution volume. This solution (0.5 mg L−1 BCP) was added to 1 g of soil in a 20 mL glass scintillation vial for a series of 25 different USDA soil series. Samples were then placed horizontally on a reciprocal shaker and allowed to equilibrate for 24 h (180 rev min-1) in the dark. Following centrifugation (20 min, 1500 × g), 2 mL of supernatant was removed and filtered (0.45 μm). Then a 1 mL aliquot of the filtered solution was mixed with 5 mL of scintillation cocktail [EcoLite(+)™; MP Biomedicals, LLC, Solon, OH] and analyzed for 14C by liquid scintillation counting (LSC) (HITACHI AccuFLEX LSC-8000, GMI Ramsey, MN, 10-minute counting window). No statistically significant sorption of the BCP to scintillation vials, syringes or syringe filters was observed (98-100% recovery, data not shown). The sorbed concentration of BCP on the soil was estimated by the following: Cs=Ci-CemV , where Ci is the initial concentration (mg L-1), Ce is the equilibrium concentration (mg L-1), V is the total volume of the liquid phase (L), and m is the mass of the soil (g). The equilibrium concentration was determined by the LSC of the liquid phase using the following equation: Ce=LSCe-Blank * CiLSCi , where LSCe is the disintegrations per minute of the sample following equilibration with the soil, Blank is the disintegrations per minute of the scintillation cocktail and vial alone, Ci is the liquid phase concentration of the initial standard (mg L-1), and LSCi are the disintegration of the corresponding BCP standards (without soil added). The partitioning coefficient (KD) is estimated by the following: KD= CSCe . Sorption Isotherms – Multiple Concentrations Sorption isotherms were generated for 7 selected soils which were selected based on the initial screening above for a range of observed KD values. The isotherm was determined utilizing initial BCP solution concentrations of 0.1, 0.5, 1, 2.5, 5, 10, and 20 mg L−1. Individual samples were run in duplicate using methods analogous to the single concentration batch KD determination described earlier. Equilibrium liquid (Ce) and solid (Cs) concentrations were then analyzed by fitting to different linear forms of four sorption models: Langmuir, Freundlich, Temkin, and the Dubinin-Radushkevich models (Horsfall, Spiff, & Abia, 2004; Hunt & He, 2015). [Usage Notes] Excel file with separate worksheets for the batch-isotherm (KD) and the multi-point isotherm datasets.

Saved in:
Bibliographic Details
Main Authors: Spokas, K. A., Gámiz, B., Schneider, S. K., Hall, K. E., Chen, Wenlin
Other Authors: Spokas, K. A. [0000-0002-5049-5959]
Format: dataset biblioteca
Language:English
Published: Dryad 2020-12-11
Online Access:http://hdl.handle.net/10261/283251
http://datadryad.org/stash/dataset/doi:10.5061/dryad.70rxwdbwd
Tags: Add Tag
No Tags, Be the first to tag this record!