Detection of palm stearin in palm oil

Slip melting point, iodine value, fatty acid and triglyceride composition measured by gas-liquid chromatography were used to detect stearin in palm oil. Three palm oils of iodine value 51.3, 53.1 and 54.7 were each mixed with four different stearins in five proportions of 2, 5, 10, 20 and 40 percent. The limits of detection for each of the techniques used were determined. The limits were governed by the types of stearin and palm oils used in the mixtures. Soft stearins (I.V. 49) when mixed with palm oils of I.V. 55 were difficult to detect. Hard stearins (I.V. 21) were more easily detectable which, when mixed with palm oils of I.V. 55, could be detected in amounts as low as 4 percent

Saved in:
Bibliographic Details
Main Authors: 100596 Oh, F.C.H., 48293 Berger, K.G., 123334 Tan, B.K., 118814 Siew, W.L., 107224 Pushparajah, E., 108427 Rajadurai, M. eds., 15747 Palm Oil Research Inst. of Malaysia, Kuala Lumpur (Malasia), 10819 Incorporated Society of Planters, Kuala Lumpur (Malasia), 35748 International Conference on Palm Oil Product Technology in the Eighties Kuala Lumpur (Malasia) 22-24 Jun 1981
Format: biblioteca
Published: Kuala Lumpur (Malasia) 1983
Subjects:ELAEIS GUINEENSIS, ACEITES DE PALMAS, ESTEARINA,
Tags: Add Tag
No Tags, Be the first to tag this record!