Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials
Objectives This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.
Main Authors: | , , , , , , , |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
Faculdade De Odontologia De Bauru - USP
2013
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572013000100080 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scielo:S1678-77572013000100080 |
---|---|
record_format |
ojs |
spelling |
oai:scielo:S1678-775720130001000802016-09-16Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materialsSAMPAIO,Renata Kirita DoiWANG,LindaCARVALHO,Rodrigo Varella deGARCIA,Eugenio JoséANDRADE,Andréa Mello deKLEIN-JÚNIOR,Celso AfonsoGRANDE,Rosa Helena MirandaMOURA,Sandra Kiss Dentin Bonding Dental adhesives Composite resins Longevity Objectives This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage.info:eu-repo/semantics/openAccessFaculdade De Odontologia De Bauru - USPJournal of Applied Oral Science v.21 n.1 20132013-02-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572013000100080en10.1590/1678-7757201302329 |
institution |
SCIELO |
collection |
OJS |
country |
Brasil |
countrycode |
BR |
component |
Revista |
access |
En linea |
databasecode |
rev-scielo-br |
tag |
revista |
region |
America del Sur |
libraryname |
SciELO |
language |
English |
format |
Digital |
author |
SAMPAIO,Renata Kirita Doi WANG,Linda CARVALHO,Rodrigo Varella de GARCIA,Eugenio José ANDRADE,Andréa Mello de KLEIN-JÚNIOR,Celso Afonso GRANDE,Rosa Helena Miranda MOURA,Sandra Kiss |
spellingShingle |
SAMPAIO,Renata Kirita Doi WANG,Linda CARVALHO,Rodrigo Varella de GARCIA,Eugenio José ANDRADE,Andréa Mello de KLEIN-JÚNIOR,Celso Afonso GRANDE,Rosa Helena Miranda MOURA,Sandra Kiss Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials |
author_facet |
SAMPAIO,Renata Kirita Doi WANG,Linda CARVALHO,Rodrigo Varella de GARCIA,Eugenio José ANDRADE,Andréa Mello de KLEIN-JÚNIOR,Celso Afonso GRANDE,Rosa Helena Miranda MOURA,Sandra Kiss |
author_sort |
SAMPAIO,Renata Kirita Doi |
title |
Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials |
title_short |
Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials |
title_full |
Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials |
title_fullStr |
Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials |
title_full_unstemmed |
Six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials |
title_sort |
six-month evaluation of a resin/dentin interface created by methacrylate and silorane-based materials |
description |
Objectives This study aimed to compare the micro-tensile bond strength of methacrylate resin systems to a silorane-based restorative system on dentin after 24 hours and six months water storage. Material and Methods The restorative systems Adper Single Bond 2/Filtek Z350 (ASB), Clearfil SE Bond/Z350 (CF), Adper SE Plus/Z350 (ASEP) and P90 Adhesive System/Filtek P90 (P90) were applied on flat dentin surfaces of 20 third molars (n=5). The restored teeth were sectioned perpendicularly to the bonding interface to obtain sticks (0.8 mm2) to be tested after 24 hours (24 h) and 6 months (6 m) of water storage, in a universal testing machine at 0.5 mm/min. The data was analyzed via two-way Analysis of Variance/Bonferroni post hoc tests at 5% global significance. Results Overall outcomes did not indicate a statistical difference for the resin systems (p=0.26) nor time (p=0.62). No interaction between material × time was detected (p=0.28). Mean standard-deviation in MPa at 24 h and 6 m were: ASB 31.38 (4.53) and 30.06 (1.95), CF 34.26 (3.47) and 32.75 (4.18), ASEP 29.54 (4.14) and 33.47 (2.47), P90 30.27 (2.03) and 31.34 (2.19). Conclusions The silorane-based system showed a similar performance to methacrylate-based materials on dentin. All systems were stable in terms of bond strength up to 6 month of water storage. |
publisher |
Faculdade De Odontologia De Bauru - USP |
publishDate |
2013 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1678-77572013000100080 |
work_keys_str_mv |
AT sampaiorenatakiritadoi sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials AT wanglinda sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials AT carvalhorodrigovarellade sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials AT garciaeugeniojose sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials AT andradeandreamellode sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials AT kleinjuniorcelsoafonso sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials AT granderosahelenamiranda sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials AT mourasandrakiss sixmonthevaluationofaresindentininterfacecreatedbymethacrylateandsiloranebasedmaterials |
_version_ |
1756428858370818048 |