Estimation procedures affect the center of pressure frequency analysis

Even though frequency analysis of body sway is widely applied in clinical studies, the lack of standardized procedures concerning power spectrum estimation may provide unreliable descriptors. Stabilometric tests were applied to 35 subjects (20-51 years, 54-95 kg, 1.6-1.9 m) and the power spectral density function was estimated for the anterior-posterior center of pressure time series. The median frequency was compared between power spectra estimated according to signal partitioning, sampling rate, test duration, and detrending methods. The median frequency reliability for different test durations was assessed using the intraclass correlation coefficient. When increasing number of segments, shortening test duration or applying linear detrending, the median frequency values increased significantly up to 137%. Even the shortest test duration provided reliable estimates as observed with the intraclass coefficient (0.74-0.89 confidence interval for a single 20-s test). Clinical assessment of balance may benefit from a standardized protocol for center of pressure spectral analysis that provides an adequate relationship between resolution and variance. An algorithm to estimate center of pressure power density spectrum is also proposed.

Saved in:
Bibliographic Details
Main Authors: Vieira,T.M.M., Oliveira,L.F., Nadal,J.
Format: Digital revista
Language:English
Published: Associação Brasileira de Divulgação Científica 2009
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2009000700012
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0100-879X2009000700012
record_format ojs
spelling oai:scielo:S0100-879X20090007000122009-06-26Estimation procedures affect the center of pressure frequency analysisVieira,T.M.M.Oliveira,L.F.Nadal,J. Center of pressure Spectral analysis Quiet standing Estimators Median frequency Even though frequency analysis of body sway is widely applied in clinical studies, the lack of standardized procedures concerning power spectrum estimation may provide unreliable descriptors. Stabilometric tests were applied to 35 subjects (20-51 years, 54-95 kg, 1.6-1.9 m) and the power spectral density function was estimated for the anterior-posterior center of pressure time series. The median frequency was compared between power spectra estimated according to signal partitioning, sampling rate, test duration, and detrending methods. The median frequency reliability for different test durations was assessed using the intraclass correlation coefficient. When increasing number of segments, shortening test duration or applying linear detrending, the median frequency values increased significantly up to 137%. Even the shortest test duration provided reliable estimates as observed with the intraclass coefficient (0.74-0.89 confidence interval for a single 20-s test). Clinical assessment of balance may benefit from a standardized protocol for center of pressure spectral analysis that provides an adequate relationship between resolution and variance. An algorithm to estimate center of pressure power density spectrum is also proposed.info:eu-repo/semantics/openAccessAssociação Brasileira de Divulgação CientíficaBrazilian Journal of Medical and Biological Research v.42 n.7 20092009-07-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2009000700012en10.1590/S0100-879X2009000700012
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Vieira,T.M.M.
Oliveira,L.F.
Nadal,J.
spellingShingle Vieira,T.M.M.
Oliveira,L.F.
Nadal,J.
Estimation procedures affect the center of pressure frequency analysis
author_facet Vieira,T.M.M.
Oliveira,L.F.
Nadal,J.
author_sort Vieira,T.M.M.
title Estimation procedures affect the center of pressure frequency analysis
title_short Estimation procedures affect the center of pressure frequency analysis
title_full Estimation procedures affect the center of pressure frequency analysis
title_fullStr Estimation procedures affect the center of pressure frequency analysis
title_full_unstemmed Estimation procedures affect the center of pressure frequency analysis
title_sort estimation procedures affect the center of pressure frequency analysis
description Even though frequency analysis of body sway is widely applied in clinical studies, the lack of standardized procedures concerning power spectrum estimation may provide unreliable descriptors. Stabilometric tests were applied to 35 subjects (20-51 years, 54-95 kg, 1.6-1.9 m) and the power spectral density function was estimated for the anterior-posterior center of pressure time series. The median frequency was compared between power spectra estimated according to signal partitioning, sampling rate, test duration, and detrending methods. The median frequency reliability for different test durations was assessed using the intraclass correlation coefficient. When increasing number of segments, shortening test duration or applying linear detrending, the median frequency values increased significantly up to 137%. Even the shortest test duration provided reliable estimates as observed with the intraclass coefficient (0.74-0.89 confidence interval for a single 20-s test). Clinical assessment of balance may benefit from a standardized protocol for center of pressure spectral analysis that provides an adequate relationship between resolution and variance. An algorithm to estimate center of pressure power density spectrum is also proposed.
publisher Associação Brasileira de Divulgação Científica
publishDate 2009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-879X2009000700012
work_keys_str_mv AT vieiratmm estimationproceduresaffectthecenterofpressurefrequencyanalysis
AT oliveiralf estimationproceduresaffectthecenterofpressurefrequencyanalysis
AT nadalj estimationproceduresaffectthecenterofpressurefrequencyanalysis
_version_ 1756391255040851968