Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method
In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC) procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid) and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione) in multivitamin tablets. The linearity of the method was excellent (R² > 0.999) over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.
Main Authors: | , , , |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
Sociedade Brasileira de Química
2013
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000700020 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scielo:S0100-40422013000700020 |
---|---|
record_format |
ojs |
spelling |
oai:scielo:S0100-404220130007000202013-09-12Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC methodKucukkolbasi,SemahatBilber,OnurAyyildiz,H. FilizKara,Huseyin simultaneous determination water-soluble and fat-soluble vitamins RP-HPLC In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC) procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid) and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione) in multivitamin tablets. The linearity of the method was excellent (R² > 0.999) over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims.info:eu-repo/semantics/openAccessSociedade Brasileira de QuímicaQuímica Nova v.36 n.7 20132013-01-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000700020en10.1590/S0100-40422013000700020 |
institution |
SCIELO |
collection |
OJS |
country |
Brasil |
countrycode |
BR |
component |
Revista |
access |
En linea |
databasecode |
rev-scielo-br |
tag |
revista |
region |
America del Sur |
libraryname |
SciELO |
language |
English |
format |
Digital |
author |
Kucukkolbasi,Semahat Bilber,Onur Ayyildiz,H. Filiz Kara,Huseyin |
spellingShingle |
Kucukkolbasi,Semahat Bilber,Onur Ayyildiz,H. Filiz Kara,Huseyin Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method |
author_facet |
Kucukkolbasi,Semahat Bilber,Onur Ayyildiz,H. Filiz Kara,Huseyin |
author_sort |
Kucukkolbasi,Semahat |
title |
Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method |
title_short |
Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method |
title_full |
Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method |
title_fullStr |
Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method |
title_full_unstemmed |
Simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an RP-HPLC method |
title_sort |
simultaneous and accurate determination of water- and fat-soluble vitamins in multivitamin tablets by using an rp-hplc method |
description |
In the present study, a reversed-phase high-performance liquid chromatographic (RP-HPLC) procedure was developed and validated for the simultaneous determination of seven water-soluble vitamins (thiamine, riboflavin, niacin, cyanocobalamin, ascorbic acid, folic acid, and p-aminobenzoic acid) and four fat-soluble vitamins (retinol acetate, cholecalciferol, α-tocopherol, and phytonadione) in multivitamin tablets. The linearity of the method was excellent (R² > 0.999) over the concentration range of 10 - 500 ng mL-1. The statistical evaluation of the method was carried out by performing the intra- and inter-day precision. The accuracy of the method was tested by measuring the average recovery; values ranged between 87.4% and 98.5% and were acceptable quantitative results that corresponded with the label claims. |
publisher |
Sociedade Brasileira de Química |
publishDate |
2013 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422013000700020 |
work_keys_str_mv |
AT kucukkolbasisemahat simultaneousandaccuratedeterminationofwaterandfatsolublevitaminsinmultivitamintabletsbyusinganrphplcmethod AT bilberonur simultaneousandaccuratedeterminationofwaterandfatsolublevitaminsinmultivitamintabletsbyusinganrphplcmethod AT ayyildizhfiliz simultaneousandaccuratedeterminationofwaterandfatsolublevitaminsinmultivitamintabletsbyusinganrphplcmethod AT karahuseyin simultaneousandaccuratedeterminationofwaterandfatsolublevitaminsinmultivitamintabletsbyusinganrphplcmethod |
_version_ |
1756387533973880832 |