Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography
A rapid and sensitive method using high performance liquid chromatography has been developed and validated for the simultaneous determination of non-steroidal anti-inflammatory drugs (NSAIDs) in pharmaceutical formulations and human serum. Six NSAIDs including: naproxen sodium, diclofenac sodium, meloxicam, flurbiprofen, tiaprofenic and mefenamic acid were analyzed simultaneously in presence of ibuprofen as internal standard on Mediterranea C18 (5 µm, 250 x 0.46 mm) column. Mobile phase comprised of methanol: acetonitrile: H2O (60:20:20, v/v; pH 3.35) and pumped at a flow rate of 1 mL min-1 using 265 nm UV detection. The method was linear over a concentration range of 0.25-50 µg mL-1 (r² = 0.9999).
Main Author: | |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
Sociedade Brasileira de Química
2012
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000500014 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scielo:S0100-40422012000500014 |
---|---|
record_format |
ojs |
spelling |
oai:scielo:S0100-404220120005000142012-07-04Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatographyNawaz,Muhammad NSAIDs serum reversed phase high performance liquid chromatography A rapid and sensitive method using high performance liquid chromatography has been developed and validated for the simultaneous determination of non-steroidal anti-inflammatory drugs (NSAIDs) in pharmaceutical formulations and human serum. Six NSAIDs including: naproxen sodium, diclofenac sodium, meloxicam, flurbiprofen, tiaprofenic and mefenamic acid were analyzed simultaneously in presence of ibuprofen as internal standard on Mediterranea C18 (5 µm, 250 x 0.46 mm) column. Mobile phase comprised of methanol: acetonitrile: H2O (60:20:20, v/v; pH 3.35) and pumped at a flow rate of 1 mL min-1 using 265 nm UV detection. The method was linear over a concentration range of 0.25-50 µg mL-1 (r² = 0.9999).info:eu-repo/semantics/openAccessSociedade Brasileira de QuímicaQuímica Nova v.35 n.5 20122012-01-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000500014en10.1590/S0100-40422012000500014 |
institution |
SCIELO |
collection |
OJS |
country |
Brasil |
countrycode |
BR |
component |
Revista |
access |
En linea |
databasecode |
rev-scielo-br |
tag |
revista |
region |
America del Sur |
libraryname |
SciELO |
language |
English |
format |
Digital |
author |
Nawaz,Muhammad |
spellingShingle |
Nawaz,Muhammad Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography |
author_facet |
Nawaz,Muhammad |
author_sort |
Nawaz,Muhammad |
title |
Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography |
title_short |
Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography |
title_full |
Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography |
title_fullStr |
Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography |
title_full_unstemmed |
Simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography |
title_sort |
simultaneous determination of non-steroidal anti-inflammatory drugs in pharmaceutical formulations and human serum by reversed phase high performance liquid chromatography |
description |
A rapid and sensitive method using high performance liquid chromatography has been developed and validated for the simultaneous determination of non-steroidal anti-inflammatory drugs (NSAIDs) in pharmaceutical formulations and human serum. Six NSAIDs including: naproxen sodium, diclofenac sodium, meloxicam, flurbiprofen, tiaprofenic and mefenamic acid were analyzed simultaneously in presence of ibuprofen as internal standard on Mediterranea C18 (5 µm, 250 x 0.46 mm) column. Mobile phase comprised of methanol: acetonitrile: H2O (60:20:20, v/v; pH 3.35) and pumped at a flow rate of 1 mL min-1 using 265 nm UV detection. The method was linear over a concentration range of 0.25-50 µg mL-1 (r² = 0.9999). |
publisher |
Sociedade Brasileira de Química |
publishDate |
2012 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422012000500014 |
work_keys_str_mv |
AT nawazmuhammad simultaneousdeterminationofnonsteroidalantiinflammatorydrugsinpharmaceuticalformulationsandhumanserumbyreversedphasehighperformanceliquidchromatography |
_version_ |
1756387476698562560 |