Water quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment
This document specifies a method for the determination of hexavalent chromium [Cr(VI)] and trivalent chromium [Cr(III)] in water by liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment. This method is applicable to the determination of Cr(VI) and Cr(III) dissolved in wastewater, surface water, groundwater, or drinking water from 0,20 μg/l to 500 μg/l of each compound as chromium (Cr) mass. Samples containing Cr at concentrations higher than the working range can be analysed following appropriate dilution of the sample.
Main Author: | |
---|---|
Format: | Texto biblioteca |
Language: | eng |
Published: |
Geneva (Switzerland) ISO
2024
|
Subjects: | water quality, Mass spectrometry, standards, |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
unfao:858267 |
---|---|
record_format |
koha |
spelling |
unfao:8582672024-06-11T11:44:01ZWater quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment International Organization for Standardization, Geneva (Switzerland) eng 175127 textGeneva (Switzerland) ISO2024engThis document specifies a method for the determination of hexavalent chromium [Cr(VI)] and trivalent chromium [Cr(III)] in water by liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment. This method is applicable to the determination of Cr(VI) and Cr(III) dissolved in wastewater, surface water, groundwater, or drinking water from 0,20 μg/l to 500 μg/l of each compound as chromium (Cr) mass. Samples containing Cr at concentrations higher than the working range can be analysed following appropriate dilution of the sample.This document specifies a method for the determination of hexavalent chromium [Cr(VI)] and trivalent chromium [Cr(III)] in water by liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment. This method is applicable to the determination of Cr(VI) and Cr(III) dissolved in wastewater, surface water, groundwater, or drinking water from 0,20 μg/l to 500 μg/l of each compound as chromium (Cr) mass. Samples containing Cr at concentrations higher than the working range can be analysed following appropriate dilution of the sample.water qualityMass spectrometrystandards |
institution |
FAO IT |
collection |
Koha |
country |
Italia |
countrycode |
IT |
component |
Bibliográfico |
access |
En linea |
databasecode |
cat-fao-it |
tag |
biblioteca |
region |
Europa del Sur |
libraryname |
David Lubin Memorial Library of FAO |
language |
eng |
topic |
water quality Mass spectrometry standards water quality Mass spectrometry standards |
spellingShingle |
water quality Mass spectrometry standards water quality Mass spectrometry standards International Organization for Standardization, Geneva (Switzerland) eng 175127 Water quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment |
description |
This document specifies a method for the determination of hexavalent chromium [Cr(VI)] and trivalent chromium [Cr(III)] in water by liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment.
This method is applicable to the determination of Cr(VI) and Cr(III) dissolved in wastewater, surface water, groundwater, or drinking water from 0,20 μg/l to 500 μg/l of each compound as chromium (Cr) mass. Samples containing Cr at concentrations higher than the working range can be analysed following appropriate dilution of the sample. |
format |
Texto |
topic_facet |
water quality Mass spectrometry standards |
author |
International Organization for Standardization, Geneva (Switzerland) eng 175127 |
author_facet |
International Organization for Standardization, Geneva (Switzerland) eng 175127 |
author_sort |
International Organization for Standardization, Geneva (Switzerland) eng 175127 |
title |
Water quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment |
title_short |
Water quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment |
title_full |
Water quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment |
title_fullStr |
Water quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment |
title_full_unstemmed |
Water quality: Determination of chromium(VI) and chromium(III) in water: Method using liquid chromatography with inductively coupled plasma mass spectrometry (LC-ICP-MS) after chelating pretreatment |
title_sort |
water quality: determination of chromium(vi) and chromium(iii) in water: method using liquid chromatography with inductively coupled plasma mass spectrometry (lc-icp-ms) after chelating pretreatment |
publisher |
Geneva (Switzerland) ISO |
publishDate |
2024 |
work_keys_str_mv |
AT internationalorganizationforstandardizationgenevaswitzerlandeng175127 waterqualitydeterminationofchromiumviandchromiumiiiinwatermethodusingliquidchromatographywithinductivelycoupledplasmamassspectrometrylcicpmsafterchelatingpretreatment |
_version_ |
1802816010990911488 |