Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires

ABSTRACT Introduction: The heat treatment of stainless steel wires is a routine clinical procedure adopted by many dentists in order to relieve the stress caused after performing bends in the archwire. Objective: This study aimed to evaluate the influence of heat treatment of stainless steel archwires with a rectangular section of 0.016 x 0.022’-in. Methods: For analysis of the dimensional stability, the anterior and posterior dimensions of forty 0.016 x 0.022-in stainless steel orthodontic archwires without heat treatment and 30 days after heat treatment were evaluated. For analysis of the mechanical properties, 12 stainless steel wire segments with the same rectangular section without heat treatment and 30 days after heat treatment were tested through tensile strength and strain tests. To evaluate if there were differences between the anterior and posterior dimensions, the results were analyzed by the Student’s t-test. To compare the tensile strength and strain between the groups, the ANOVA test was used. The level of significance adopted was 95% (p< 0.05). Results: The heat treatment did not stop the expansion of archwires 30 days after their preparation, and there was no statistical difference in the tensile strength and strain tests with and without heat treatment. Conclusion: From the findings of this study, it can be conclude that the mechanical behavior of heat-treated stainless steel archwires is similar to that of archwires not subjected to heat treatment.

Saved in:
Bibliographic Details
Main Authors: Sepúlveda,Clariana Hoehne, Gontijo,Sávio Morato de Lacerda, Santos,Leandro de Arruda, Drummond,Alexandre Fortes, Menezes,Leonardo Foresti Soares de, Neves,Leniana Santos, França,Esdras Campos
Format: Digital revista
Language:English
Published: Dental Press International 2019
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512019000100068
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S2176-94512019000100068
record_format ojs
spelling oai:scielo:S2176-945120190001000682019-03-26Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wiresSepúlveda,Clariana HoehneGontijo,Sávio Morato de LacerdaSantos,Leandro de ArrudaDrummond,Alexandre FortesMenezes,Leonardo Foresti Soares deNeves,Leniana SantosFrança,Esdras Campos Orthodontic Thermic treatment Stainless steel ABSTRACT Introduction: The heat treatment of stainless steel wires is a routine clinical procedure adopted by many dentists in order to relieve the stress caused after performing bends in the archwire. Objective: This study aimed to evaluate the influence of heat treatment of stainless steel archwires with a rectangular section of 0.016 x 0.022’-in. Methods: For analysis of the dimensional stability, the anterior and posterior dimensions of forty 0.016 x 0.022-in stainless steel orthodontic archwires without heat treatment and 30 days after heat treatment were evaluated. For analysis of the mechanical properties, 12 stainless steel wire segments with the same rectangular section without heat treatment and 30 days after heat treatment were tested through tensile strength and strain tests. To evaluate if there were differences between the anterior and posterior dimensions, the results were analyzed by the Student’s t-test. To compare the tensile strength and strain between the groups, the ANOVA test was used. The level of significance adopted was 95% (p< 0.05). Results: The heat treatment did not stop the expansion of archwires 30 days after their preparation, and there was no statistical difference in the tensile strength and strain tests with and without heat treatment. Conclusion: From the findings of this study, it can be conclude that the mechanical behavior of heat-treated stainless steel archwires is similar to that of archwires not subjected to heat treatment.info:eu-repo/semantics/openAccessDental Press InternationalDental Press Journal of Orthodontics v.24 n.1 20192019-02-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512019000100068en10.1590/2177-6709.24.1.068-073.oar
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Sepúlveda,Clariana Hoehne
Gontijo,Sávio Morato de Lacerda
Santos,Leandro de Arruda
Drummond,Alexandre Fortes
Menezes,Leonardo Foresti Soares de
Neves,Leniana Santos
França,Esdras Campos
spellingShingle Sepúlveda,Clariana Hoehne
Gontijo,Sávio Morato de Lacerda
Santos,Leandro de Arruda
Drummond,Alexandre Fortes
Menezes,Leonardo Foresti Soares de
Neves,Leniana Santos
França,Esdras Campos
Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires
author_facet Sepúlveda,Clariana Hoehne
Gontijo,Sávio Morato de Lacerda
Santos,Leandro de Arruda
Drummond,Alexandre Fortes
Menezes,Leonardo Foresti Soares de
Neves,Leniana Santos
França,Esdras Campos
author_sort Sepúlveda,Clariana Hoehne
title Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires
title_short Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires
title_full Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires
title_fullStr Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires
title_full_unstemmed Influence of heat treatment on the mechanical properties of CrNi stainless steel orthodontic wires
title_sort influence of heat treatment on the mechanical properties of crni stainless steel orthodontic wires
description ABSTRACT Introduction: The heat treatment of stainless steel wires is a routine clinical procedure adopted by many dentists in order to relieve the stress caused after performing bends in the archwire. Objective: This study aimed to evaluate the influence of heat treatment of stainless steel archwires with a rectangular section of 0.016 x 0.022’-in. Methods: For analysis of the dimensional stability, the anterior and posterior dimensions of forty 0.016 x 0.022-in stainless steel orthodontic archwires without heat treatment and 30 days after heat treatment were evaluated. For analysis of the mechanical properties, 12 stainless steel wire segments with the same rectangular section without heat treatment and 30 days after heat treatment were tested through tensile strength and strain tests. To evaluate if there were differences between the anterior and posterior dimensions, the results were analyzed by the Student’s t-test. To compare the tensile strength and strain between the groups, the ANOVA test was used. The level of significance adopted was 95% (p< 0.05). Results: The heat treatment did not stop the expansion of archwires 30 days after their preparation, and there was no statistical difference in the tensile strength and strain tests with and without heat treatment. Conclusion: From the findings of this study, it can be conclude that the mechanical behavior of heat-treated stainless steel archwires is similar to that of archwires not subjected to heat treatment.
publisher Dental Press International
publishDate 2019
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2176-94512019000100068
work_keys_str_mv AT sepulvedaclarianahoehne influenceofheattreatmentonthemechanicalpropertiesofcrnistainlesssteelorthodonticwires
AT gontijosaviomoratodelacerda influenceofheattreatmentonthemechanicalpropertiesofcrnistainlesssteelorthodonticwires
AT santosleandrodearruda influenceofheattreatmentonthemechanicalpropertiesofcrnistainlesssteelorthodonticwires
AT drummondalexandrefortes influenceofheattreatmentonthemechanicalpropertiesofcrnistainlesssteelorthodonticwires
AT menezesleonardoforestisoaresde influenceofheattreatmentonthemechanicalpropertiesofcrnistainlesssteelorthodonticwires
AT neveslenianasantos influenceofheattreatmentonthemechanicalpropertiesofcrnistainlesssteelorthodonticwires
AT francaesdrascampos influenceofheattreatmentonthemechanicalpropertiesofcrnistainlesssteelorthodonticwires
_version_ 1756439046342574080