Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OES

Abstract This work describes the analysis of different chicken tissues (gizzard, heart, and liver) both raw and cooked with seasonings in different types of cooking pots (iron pot, , aluminum pot and hammered aluminum pot) commonly used in Brazil. The samples were decomposed using microwave-assisted digestion with diluted nitric acid; and the contents of Al, Ca, Cu, Fe, Mn and Ni were determined using Microwave Induced Plasma Optical Emission Spectrometry (MIP OES). The Fe content was also determined by Flame Atomic Absorption Spectrometry, and the comparison showed good accuracy of the method. The limits of quantification were below 0.011 mg kg-1, showing adequate detectability. Cooking in the different pots increased the ash and protein contents as well as decreased the moisture content. Box-plot and Principal Components Analysis showed that Ca and Fe contents present the largest variations in the samples, followed by Al and moisture. The variables Al, Cu, Mn, Ni, ash, and protein presented similar behavior after cooking in all different pots. In addition, liver cooked in both iron and hammered aluminum pots presented similar Fe contents, while gizzard and heart showed similar Ca contents.

Saved in:
Bibliographic Details
Main Authors: Campos,Náira da Silva, Alvarenga,Flávia Barbosa Magalhães, Sabarense,Céphora Maria, Oliveira,Marcone Augusto Leal de, Timm,Janaína Garcia, Vieira,Mariana Antunes, Sousa,Rafael Arromba de
Format: Digital revista
Language:English
Published: Instituto de Tecnologia de Alimentos - ITAL 2020
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-67232020000100459
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S1981-67232020000100459
record_format ojs
spelling oai:scielo:S1981-672320200001004592020-07-24Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OESCampos,Náira da SilvaAlvarenga,Flávia Barbosa MagalhãesSabarense,Céphora MariaOliveira,Marcone Augusto Leal deTimm,Janaína GarciaVieira,Mariana AntunesSousa,Rafael Arromba de Chicken meat Iron pot Hammered aluminum pot Aluminum pot Metals MIP OES Abstract This work describes the analysis of different chicken tissues (gizzard, heart, and liver) both raw and cooked with seasonings in different types of cooking pots (iron pot, , aluminum pot and hammered aluminum pot) commonly used in Brazil. The samples were decomposed using microwave-assisted digestion with diluted nitric acid; and the contents of Al, Ca, Cu, Fe, Mn and Ni were determined using Microwave Induced Plasma Optical Emission Spectrometry (MIP OES). The Fe content was also determined by Flame Atomic Absorption Spectrometry, and the comparison showed good accuracy of the method. The limits of quantification were below 0.011 mg kg-1, showing adequate detectability. Cooking in the different pots increased the ash and protein contents as well as decreased the moisture content. Box-plot and Principal Components Analysis showed that Ca and Fe contents present the largest variations in the samples, followed by Al and moisture. The variables Al, Cu, Mn, Ni, ash, and protein presented similar behavior after cooking in all different pots. In addition, liver cooked in both iron and hammered aluminum pots presented similar Fe contents, while gizzard and heart showed similar Ca contents.info:eu-repo/semantics/openAccessInstituto de Tecnologia de Alimentos - ITALBrazilian Journal of Food Technology v.23 20202020-01-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-67232020000100459en10.1590/1981-6723.30819
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Campos,Náira da Silva
Alvarenga,Flávia Barbosa Magalhães
Sabarense,Céphora Maria
Oliveira,Marcone Augusto Leal de
Timm,Janaína Garcia
Vieira,Mariana Antunes
Sousa,Rafael Arromba de
spellingShingle Campos,Náira da Silva
Alvarenga,Flávia Barbosa Magalhães
Sabarense,Céphora Maria
Oliveira,Marcone Augusto Leal de
Timm,Janaína Garcia
Vieira,Mariana Antunes
Sousa,Rafael Arromba de
Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OES
author_facet Campos,Náira da Silva
Alvarenga,Flávia Barbosa Magalhães
Sabarense,Céphora Maria
Oliveira,Marcone Augusto Leal de
Timm,Janaína Garcia
Vieira,Mariana Antunes
Sousa,Rafael Arromba de
author_sort Campos,Náira da Silva
title Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OES
title_short Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OES
title_full Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OES
title_fullStr Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OES
title_full_unstemmed Evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by MIP OES
title_sort evaluation of the influence of different cooking pot types on the metallic elements content in edible chicken tissues by mip oes
description Abstract This work describes the analysis of different chicken tissues (gizzard, heart, and liver) both raw and cooked with seasonings in different types of cooking pots (iron pot, , aluminum pot and hammered aluminum pot) commonly used in Brazil. The samples were decomposed using microwave-assisted digestion with diluted nitric acid; and the contents of Al, Ca, Cu, Fe, Mn and Ni were determined using Microwave Induced Plasma Optical Emission Spectrometry (MIP OES). The Fe content was also determined by Flame Atomic Absorption Spectrometry, and the comparison showed good accuracy of the method. The limits of quantification were below 0.011 mg kg-1, showing adequate detectability. Cooking in the different pots increased the ash and protein contents as well as decreased the moisture content. Box-plot and Principal Components Analysis showed that Ca and Fe contents present the largest variations in the samples, followed by Al and moisture. The variables Al, Cu, Mn, Ni, ash, and protein presented similar behavior after cooking in all different pots. In addition, liver cooked in both iron and hammered aluminum pots presented similar Fe contents, while gizzard and heart showed similar Ca contents.
publisher Instituto de Tecnologia de Alimentos - ITAL
publishDate 2020
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-67232020000100459
work_keys_str_mv AT camposnairadasilva evaluationoftheinfluenceofdifferentcookingpottypesonthemetallicelementscontentinediblechickentissuesbymipoes
AT alvarengaflaviabarbosamagalhaes evaluationoftheinfluenceofdifferentcookingpottypesonthemetallicelementscontentinediblechickentissuesbymipoes
AT sabarensecephoramaria evaluationoftheinfluenceofdifferentcookingpottypesonthemetallicelementscontentinediblechickentissuesbymipoes
AT oliveiramarconeaugustolealde evaluationoftheinfluenceofdifferentcookingpottypesonthemetallicelementscontentinediblechickentissuesbymipoes
AT timmjanainagarcia evaluationoftheinfluenceofdifferentcookingpottypesonthemetallicelementscontentinediblechickentissuesbymipoes
AT vieiramarianaantunes evaluationoftheinfluenceofdifferentcookingpottypesonthemetallicelementscontentinediblechickentissuesbymipoes
AT sousarafaelarrombade evaluationoftheinfluenceofdifferentcookingpottypesonthemetallicelementscontentinediblechickentissuesbymipoes
_version_ 1756435056963878912