Tightening techniques for the retaining screws of universal abutment
Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque); and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001). The H20+R technique showed the highest maintained torque (p=0.003), but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque.
Main Authors: | , , , , , |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
Universidade Estadual Paulista Júlio de Mesquita Filho
2016
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000300146 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scielo:S1807-25772016000300146 |
---|---|
record_format |
ojs |
spelling |
oai:scielo:S1807-257720160003001462016-06-22Tightening techniques for the retaining screws of universal abutmentREGALIN,Alexandre WittcinskiALESSANDRETTI,RodrigoFEDERIZZI,LeonardoGOMES,Érica AlvesBACCHI,AtaísSPAZZIN,Aloísio Oro Implant-supported dental prosthesis dental implant-abutment design torque Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque); and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001). The H20+R technique showed the highest maintained torque (p=0.003), but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque.info:eu-repo/semantics/openAccessUniversidade Estadual Paulista Júlio de Mesquita FilhoRevista de Odontologia da UNESP v.45 n.3 20162016-06-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000300146en10.1590/1807-2577.23515 |
institution |
SCIELO |
collection |
OJS |
country |
Brasil |
countrycode |
BR |
component |
Revista |
access |
En linea |
databasecode |
rev-scielo-br |
tag |
revista |
region |
America del Sur |
libraryname |
SciELO |
language |
English |
format |
Digital |
author |
REGALIN,Alexandre Wittcinski ALESSANDRETTI,Rodrigo FEDERIZZI,Leonardo GOMES,Érica Alves BACCHI,Ataís SPAZZIN,Aloísio Oro |
spellingShingle |
REGALIN,Alexandre Wittcinski ALESSANDRETTI,Rodrigo FEDERIZZI,Leonardo GOMES,Érica Alves BACCHI,Ataís SPAZZIN,Aloísio Oro Tightening techniques for the retaining screws of universal abutment |
author_facet |
REGALIN,Alexandre Wittcinski ALESSANDRETTI,Rodrigo FEDERIZZI,Leonardo GOMES,Érica Alves BACCHI,Ataís SPAZZIN,Aloísio Oro |
author_sort |
REGALIN,Alexandre Wittcinski |
title |
Tightening techniques for the retaining screws of universal abutment |
title_short |
Tightening techniques for the retaining screws of universal abutment |
title_full |
Tightening techniques for the retaining screws of universal abutment |
title_fullStr |
Tightening techniques for the retaining screws of universal abutment |
title_full_unstemmed |
Tightening techniques for the retaining screws of universal abutment |
title_sort |
tightening techniques for the retaining screws of universal abutment |
description |
Abstract Purpose This study evaluated the torque maintenance of universal abutment retaining screws using different tightening techniques, and coated or uncoated screws. Material and method The screws were tightened to implants as following: Control – 32 Ncm torque; H20 – holding 32 Ncm torque for 20 s; R – 32 Ncm torque, repeated after 10 min (retorque); and H20+R – combining the two tightening techniques. Titanium and coated screws were also evaluated. Result Statistical analysis showed higher maintained torque for titanium screws (p<0.001). The H20+R technique showed the highest maintained torque (p=0.003), but the H20 technique’s maintained torque was similar. Conclusion Titanium screws associating the two tightening techniques can improve maintained torque. |
publisher |
Universidade Estadual Paulista Júlio de Mesquita Filho |
publishDate |
2016 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1807-25772016000300146 |
work_keys_str_mv |
AT regalinalexandrewittcinski tighteningtechniquesfortheretainingscrewsofuniversalabutment AT alessandrettirodrigo tighteningtechniquesfortheretainingscrewsofuniversalabutment AT federizzileonardo tighteningtechniquesfortheretainingscrewsofuniversalabutment AT gomesericaalves tighteningtechniquesfortheretainingscrewsofuniversalabutment AT bacchiatais tighteningtechniquesfortheretainingscrewsofuniversalabutment AT spazzinaloisiooro tighteningtechniquesfortheretainingscrewsofuniversalabutment |
_version_ |
1756431849101459456 |