Transcutaneous electric nerve stimulation for post-Cesarean section analgesia

ABSTRACT BACKGROUND AND OBJECTIVES: Physiotherapeutic resources, such as transcutaneous electric nerve stimulation, used in the post-partum period are important to promote relief of pain and discomfort induced by surgical incision, thus decreasing hospitalization time and hospital costs with the use of drugs. This study aimed at measuring pain at Cesarean section incision before and after transcutaneous electric nerve stimulation. METHODS: This is a clinical, randomized study with blind evaluator and comparative analysis between groups. Participated in the study 60 mothers in the postpartum period of Cesarean section, who were equally distributed between intervention group (IG) and control group (CG), where the intervention group has received transcutaneous electric nerve stimulation for 30 minutes, with frequency of 100Hz and pulse width of 100ms. Visual analog scale was used as evaluation tool. RESULTS: When comparing pain intensity with the visual analog scale before and after electric stimulation, there has been statistical difference (p=0.001), since pre-stimulation pain median was 45.00 (36.00-60.00) and post-stimulation median was 15.50 (5.75-27.50). When comparing groups before intervention there has been no difference between them with regard to pain evaluated by the visual analog scale (p=0.948). Mean for CG was 47.70 (25.03) and for IG it was 48.10 (22.33). When comparing final results between groups did not significant difference (p=0.047), where CG median was 30.50 (13.50-53.25) and IG median was 15.50 (5.75-27.50). CONCLUSION: Transcutaneous electric nerve stimulation is effective to relieve acute pain in the postoperative period of Cesarean section, thus making postpartum women more independent and active to perform their daily life activities.

Saved in:
Bibliographic Details
Main Authors: Alves,Elaine Maria Souza, Rabêlo,Tauanny Nazário, Santos,Maria Gabriela Reis, Souza,Isadora Guimarães, Lima,Paulo Autran Leite, Santana,Licia Santos
Format: Digital revista
Language:English
Published: Sociedade Brasileira para o Estudo da Dor 2015
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-00132015000400263
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S1806-00132015000400263
record_format ojs
spelling oai:scielo:S1806-001320150004002632015-12-07Transcutaneous electric nerve stimulation for post-Cesarean section analgesiaAlves,Elaine Maria SouzaRabêlo,Tauanny NazárioSantos,Maria Gabriela ReisSouza,Isadora GuimarãesLima,Paulo Autran LeiteSantana,Licia Santos Cesarean section Pain Physiotherapy ABSTRACT BACKGROUND AND OBJECTIVES: Physiotherapeutic resources, such as transcutaneous electric nerve stimulation, used in the post-partum period are important to promote relief of pain and discomfort induced by surgical incision, thus decreasing hospitalization time and hospital costs with the use of drugs. This study aimed at measuring pain at Cesarean section incision before and after transcutaneous electric nerve stimulation. METHODS: This is a clinical, randomized study with blind evaluator and comparative analysis between groups. Participated in the study 60 mothers in the postpartum period of Cesarean section, who were equally distributed between intervention group (IG) and control group (CG), where the intervention group has received transcutaneous electric nerve stimulation for 30 minutes, with frequency of 100Hz and pulse width of 100ms. Visual analog scale was used as evaluation tool. RESULTS: When comparing pain intensity with the visual analog scale before and after electric stimulation, there has been statistical difference (p=0.001), since pre-stimulation pain median was 45.00 (36.00-60.00) and post-stimulation median was 15.50 (5.75-27.50). When comparing groups before intervention there has been no difference between them with regard to pain evaluated by the visual analog scale (p=0.948). Mean for CG was 47.70 (25.03) and for IG it was 48.10 (22.33). When comparing final results between groups did not significant difference (p=0.047), where CG median was 30.50 (13.50-53.25) and IG median was 15.50 (5.75-27.50). CONCLUSION: Transcutaneous electric nerve stimulation is effective to relieve acute pain in the postoperative period of Cesarean section, thus making postpartum women more independent and active to perform their daily life activities.info:eu-repo/semantics/openAccessSociedade Brasileira para o Estudo da DorRevista Dor v.16 n.4 20152015-12-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-00132015000400263en10.5935/1806-0013.20150053
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Alves,Elaine Maria Souza
Rabêlo,Tauanny Nazário
Santos,Maria Gabriela Reis
Souza,Isadora Guimarães
Lima,Paulo Autran Leite
Santana,Licia Santos
spellingShingle Alves,Elaine Maria Souza
Rabêlo,Tauanny Nazário
Santos,Maria Gabriela Reis
Souza,Isadora Guimarães
Lima,Paulo Autran Leite
Santana,Licia Santos
Transcutaneous electric nerve stimulation for post-Cesarean section analgesia
author_facet Alves,Elaine Maria Souza
Rabêlo,Tauanny Nazário
Santos,Maria Gabriela Reis
Souza,Isadora Guimarães
Lima,Paulo Autran Leite
Santana,Licia Santos
author_sort Alves,Elaine Maria Souza
title Transcutaneous electric nerve stimulation for post-Cesarean section analgesia
title_short Transcutaneous electric nerve stimulation for post-Cesarean section analgesia
title_full Transcutaneous electric nerve stimulation for post-Cesarean section analgesia
title_fullStr Transcutaneous electric nerve stimulation for post-Cesarean section analgesia
title_full_unstemmed Transcutaneous electric nerve stimulation for post-Cesarean section analgesia
title_sort transcutaneous electric nerve stimulation for post-cesarean section analgesia
description ABSTRACT BACKGROUND AND OBJECTIVES: Physiotherapeutic resources, such as transcutaneous electric nerve stimulation, used in the post-partum period are important to promote relief of pain and discomfort induced by surgical incision, thus decreasing hospitalization time and hospital costs with the use of drugs. This study aimed at measuring pain at Cesarean section incision before and after transcutaneous electric nerve stimulation. METHODS: This is a clinical, randomized study with blind evaluator and comparative analysis between groups. Participated in the study 60 mothers in the postpartum period of Cesarean section, who were equally distributed between intervention group (IG) and control group (CG), where the intervention group has received transcutaneous electric nerve stimulation for 30 minutes, with frequency of 100Hz and pulse width of 100ms. Visual analog scale was used as evaluation tool. RESULTS: When comparing pain intensity with the visual analog scale before and after electric stimulation, there has been statistical difference (p=0.001), since pre-stimulation pain median was 45.00 (36.00-60.00) and post-stimulation median was 15.50 (5.75-27.50). When comparing groups before intervention there has been no difference between them with regard to pain evaluated by the visual analog scale (p=0.948). Mean for CG was 47.70 (25.03) and for IG it was 48.10 (22.33). When comparing final results between groups did not significant difference (p=0.047), where CG median was 30.50 (13.50-53.25) and IG median was 15.50 (5.75-27.50). CONCLUSION: Transcutaneous electric nerve stimulation is effective to relieve acute pain in the postoperative period of Cesarean section, thus making postpartum women more independent and active to perform their daily life activities.
publisher Sociedade Brasileira para o Estudo da Dor
publishDate 2015
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-00132015000400263
work_keys_str_mv AT alveselainemariasouza transcutaneouselectricnervestimulationforpostcesareansectionanalgesia
AT rabelotauannynazario transcutaneouselectricnervestimulationforpostcesareansectionanalgesia
AT santosmariagabrielareis transcutaneouselectricnervestimulationforpostcesareansectionanalgesia
AT souzaisadoraguimaraes transcutaneouselectricnervestimulationforpostcesareansectionanalgesia
AT limapauloautranleite transcutaneouselectricnervestimulationforpostcesareansectionanalgesia
AT santanaliciasantos transcutaneouselectricnervestimulationforpostcesareansectionanalgesia
_version_ 1756430519286890496