Compression specific toughness of normal strength steel fiber reinforced concrete (NSSFRC) and high strength steel fiber reinforced concrete (HSSFRC)

Compression toughness tests were carried out on concrete cylinders reinforced with three different aspect ratios of hooked-end steel fibers 60, 75, and 83 and six different percentages of steel fibers 0.5, 1.0, 1.25, 1.5, 1.75, and 2.0% by volume of concrete. The w/c ratio used for the normal strength steel fiber reinforced concrete mixes (NSSFRC) was 0.55, and the water-cementitious ratio (w/c+s) for the high strength fiber reinforced concrete mixes (HSSFRC) was 0.31. For each mix, three test cylinders were tested for compression specific toughness. The effect of fiber reinforcement index: volume of fibers × length/diameter ratio on compression specific toughness and also on the relationship between these two properties is presented in this paper. As a result, (a) equations are proposed to quantify the effect of fibers on compression toughness ratio of concrete in terms of FRI, (b) equations obtained in terms of FRI and compression specific toughness of plain concrete to estimate both compression specific toughness of NSSFRC and HSSFRC (N.m), (c) equations obtained which represent the relationship between compression toughness index and FRI for NSSFRC and HSSFRC, respectively, and (d) equations obtained to quantify the relationship between compression specific toughness index and fiber reinforcement index for NSSFRC and HSSFRC, respectively. The proposed equations give good correlation with the experimental values.

Saved in:
Bibliographic Details
Main Authors: Marara,Khaled, Erenb,Özgür, Yitmena,İbrahim
Format: Digital revista
Language:English
Published: ABM, ABC, ABPol 2011
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392011000200017
Tags: Add Tag
No Tags, Be the first to tag this record!

Similar Items