Validity and reliability of clinical tests for assessing passive ankle stiffness

BACKGROUND: The presence of inadequate levels of passive ankle stiffness have been associated with the occurrence of movement disorders, the development of pathological conditions and the reduction in the performance of functional activities such as walking, running and jumping. Therefore, clinical tests to evaluate ankle stiffness may be useful for the physical therapy assessment. OBJECTIVES: To investigate the concurrent validity and the intra- and inter-examiner reliability of clinical measures developed to assess passive stiffness of the ankle joint during dorsiflexion movement. METHODS: Fifteen healthy participants underwent to test-retest evaluations of their ankles by two examiners. Two clinical measures were performed: 'position of first detectable resistance' and 'change in passive resistance torque'. The results of these tests were compared to the passive stiffness measured with an isokinetic dynamometer, in which the electromyography activity of specific muscles was monitored to ensure that the test was performed passively (gold standard measure). RESULTS: Pearson correlation coefficients ranged from r=-0.81 to -0.88 (p<0.001) for the correlation between the passive ankle stiffness measured with the isokinetic dynamometer and the results of the clinical measure 'position of the first detectable resistance'. For the measure of 'change in passive resistance torque', these coefficients ranged from r=0.72 to 0.83 (p<0.004). The Intraclass Correlation Coefficients (ICCs) for the intra- and inter-examiner reliability ranged from 0.75 to 0.98. CONCLUSION: The clinical measures presented satisfactory validity and reliability to be used in clinical practice.

Saved in:
Bibliographic Details
Main Authors: Araújo,Vanessa L., Carvalhais,Viviane O. C., Souza,Thales R., Ocarino,Juliana M., Gonçalves,Gabriela G. P., Fonseca,Sérgio T.
Format: Digital revista
Language:English
Published: Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2011
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552011000200013
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S1413-35552011000200013
record_format ojs
spelling oai:scielo:S1413-355520110002000132011-07-18Validity and reliability of clinical tests for assessing passive ankle stiffnessAraújo,Vanessa L.Carvalhais,Viviane O. C.Souza,Thales R.Ocarino,Juliana M.Gonçalves,Gabriela G. P.Fonseca,Sérgio T. passive stiffness clinical test ankle validity of tests reproducibility of results BACKGROUND: The presence of inadequate levels of passive ankle stiffness have been associated with the occurrence of movement disorders, the development of pathological conditions and the reduction in the performance of functional activities such as walking, running and jumping. Therefore, clinical tests to evaluate ankle stiffness may be useful for the physical therapy assessment. OBJECTIVES: To investigate the concurrent validity and the intra- and inter-examiner reliability of clinical measures developed to assess passive stiffness of the ankle joint during dorsiflexion movement. METHODS: Fifteen healthy participants underwent to test-retest evaluations of their ankles by two examiners. Two clinical measures were performed: 'position of first detectable resistance' and 'change in passive resistance torque'. The results of these tests were compared to the passive stiffness measured with an isokinetic dynamometer, in which the electromyography activity of specific muscles was monitored to ensure that the test was performed passively (gold standard measure). RESULTS: Pearson correlation coefficients ranged from r=-0.81 to -0.88 (p<0.001) for the correlation between the passive ankle stiffness measured with the isokinetic dynamometer and the results of the clinical measure 'position of the first detectable resistance'. For the measure of 'change in passive resistance torque', these coefficients ranged from r=0.72 to 0.83 (p<0.004). The Intraclass Correlation Coefficients (ICCs) for the intra- and inter-examiner reliability ranged from 0.75 to 0.98. CONCLUSION: The clinical measures presented satisfactory validity and reliability to be used in clinical practice.info:eu-repo/semantics/openAccessAssociação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia Brazilian Journal of Physical Therapy v.15 n.2 20112011-04-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552011000200013en10.1590/S1413-35552011000200013
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Araújo,Vanessa L.
Carvalhais,Viviane O. C.
Souza,Thales R.
Ocarino,Juliana M.
Gonçalves,Gabriela G. P.
Fonseca,Sérgio T.
spellingShingle Araújo,Vanessa L.
Carvalhais,Viviane O. C.
Souza,Thales R.
Ocarino,Juliana M.
Gonçalves,Gabriela G. P.
Fonseca,Sérgio T.
Validity and reliability of clinical tests for assessing passive ankle stiffness
author_facet Araújo,Vanessa L.
Carvalhais,Viviane O. C.
Souza,Thales R.
Ocarino,Juliana M.
Gonçalves,Gabriela G. P.
Fonseca,Sérgio T.
author_sort Araújo,Vanessa L.
title Validity and reliability of clinical tests for assessing passive ankle stiffness
title_short Validity and reliability of clinical tests for assessing passive ankle stiffness
title_full Validity and reliability of clinical tests for assessing passive ankle stiffness
title_fullStr Validity and reliability of clinical tests for assessing passive ankle stiffness
title_full_unstemmed Validity and reliability of clinical tests for assessing passive ankle stiffness
title_sort validity and reliability of clinical tests for assessing passive ankle stiffness
description BACKGROUND: The presence of inadequate levels of passive ankle stiffness have been associated with the occurrence of movement disorders, the development of pathological conditions and the reduction in the performance of functional activities such as walking, running and jumping. Therefore, clinical tests to evaluate ankle stiffness may be useful for the physical therapy assessment. OBJECTIVES: To investigate the concurrent validity and the intra- and inter-examiner reliability of clinical measures developed to assess passive stiffness of the ankle joint during dorsiflexion movement. METHODS: Fifteen healthy participants underwent to test-retest evaluations of their ankles by two examiners. Two clinical measures were performed: 'position of first detectable resistance' and 'change in passive resistance torque'. The results of these tests were compared to the passive stiffness measured with an isokinetic dynamometer, in which the electromyography activity of specific muscles was monitored to ensure that the test was performed passively (gold standard measure). RESULTS: Pearson correlation coefficients ranged from r=-0.81 to -0.88 (p<0.001) for the correlation between the passive ankle stiffness measured with the isokinetic dynamometer and the results of the clinical measure 'position of the first detectable resistance'. For the measure of 'change in passive resistance torque', these coefficients ranged from r=0.72 to 0.83 (p<0.004). The Intraclass Correlation Coefficients (ICCs) for the intra- and inter-examiner reliability ranged from 0.75 to 0.98. CONCLUSION: The clinical measures presented satisfactory validity and reliability to be used in clinical practice.
publisher Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia
publishDate 2011
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552011000200013
work_keys_str_mv AT araujovanessal validityandreliabilityofclinicaltestsforassessingpassiveanklestiffness
AT carvalhaisvivianeoc validityandreliabilityofclinicaltestsforassessingpassiveanklestiffness
AT souzathalesr validityandreliabilityofclinicaltestsforassessingpassiveanklestiffness
AT ocarinojulianam validityandreliabilityofclinicaltestsforassessingpassiveanklestiffness
AT goncalvesgabrielagp validityandreliabilityofclinicaltestsforassessingpassiveanklestiffness
AT fonsecasergiot validityandreliabilityofclinicaltestsforassessingpassiveanklestiffness
_version_ 1756413753973276672