Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical composition

The essential oil of Marchantia convoluta was obtained by supercritical (carbon dioxide) extraction using methanol as a modifier. Global yields were determined according to the orthogonal design. The effects of different parameters, such as pressure, temperature, modifier volume and extraction time, on the supercritical fluid extraction (SFE) of essential oil from M. convoluta were investigated. Maximum global yields were obtained using the following conditions: extraction temperature, 35ºC; dynamic time, 35 min; pressure, 15 Mpa and modifier volume, 40 mL. The essential oil extract was analyzed by capillary gas chromatography with mass spectrometric detector (GC-MS). The compounds were identified according to their retention indices and mass spectra (EI, 70 eV). The results from GC-MS and literature were compared.

Saved in:
Bibliographic Details
Main Authors: Xiao,Jian Bo, Chen,Jing Wen, Xu,Ming
Format: Digital revista
Language:English
Published: Pontificia Universidad Católica de Valparaíso 2007
Online Access:http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-34582007000100013
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0717-34582007000100013
record_format ojs
spelling oai:scielo:S0717-345820070001000132007-08-14Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical compositionXiao,Jian BoChen,Jing WenXu,Ming GC-MS supercritical fluid extraction yields The essential oil of Marchantia convoluta was obtained by supercritical (carbon dioxide) extraction using methanol as a modifier. Global yields were determined according to the orthogonal design. The effects of different parameters, such as pressure, temperature, modifier volume and extraction time, on the supercritical fluid extraction (SFE) of essential oil from M. convoluta were investigated. Maximum global yields were obtained using the following conditions: extraction temperature, 35ºC; dynamic time, 35 min; pressure, 15 Mpa and modifier volume, 40 mL. The essential oil extract was analyzed by capillary gas chromatography with mass spectrometric detector (GC-MS). The compounds were identified according to their retention indices and mass spectra (EI, 70 eV). The results from GC-MS and literature were compared.info:eu-repo/semantics/openAccessPontificia Universidad Católica de ValparaísoElectronic Journal of Biotechnology v.10 n.1 20072007-01-01text/htmlhttp://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-34582007000100013en10.4067/S0717-34582007000100013
institution SCIELO
collection OJS
country Chile
countrycode CL
component Revista
access En linea
databasecode rev-scielo-cl
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Xiao,Jian Bo
Chen,Jing Wen
Xu,Ming
spellingShingle Xiao,Jian Bo
Chen,Jing Wen
Xu,Ming
Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical composition
author_facet Xiao,Jian Bo
Chen,Jing Wen
Xu,Ming
author_sort Xiao,Jian Bo
title Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical composition
title_short Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical composition
title_full Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical composition
title_fullStr Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical composition
title_full_unstemmed Supercritical fluid CO2 extraction of essential oil from Marchantia convoluta: global yields and extract chemical composition
title_sort supercritical fluid co2 extraction of essential oil from marchantia convoluta: global yields and extract chemical composition
description The essential oil of Marchantia convoluta was obtained by supercritical (carbon dioxide) extraction using methanol as a modifier. Global yields were determined according to the orthogonal design. The effects of different parameters, such as pressure, temperature, modifier volume and extraction time, on the supercritical fluid extraction (SFE) of essential oil from M. convoluta were investigated. Maximum global yields were obtained using the following conditions: extraction temperature, 35ºC; dynamic time, 35 min; pressure, 15 Mpa and modifier volume, 40 mL. The essential oil extract was analyzed by capillary gas chromatography with mass spectrometric detector (GC-MS). The compounds were identified according to their retention indices and mass spectra (EI, 70 eV). The results from GC-MS and literature were compared.
publisher Pontificia Universidad Católica de Valparaíso
publishDate 2007
url http://www.scielo.cl/scielo.php?script=sci_arttext&pid=S0717-34582007000100013
work_keys_str_mv AT xiaojianbo supercriticalfluidco2extractionofessentialoilfrommarchantiaconvolutaglobalyieldsandextractchemicalcomposition
AT chenjingwen supercriticalfluidco2extractionofessentialoilfrommarchantiaconvolutaglobalyieldsandextractchemicalcomposition
AT xuming supercriticalfluidco2extractionofessentialoilfrommarchantiaconvolutaglobalyieldsandextractchemicalcomposition
_version_ 1755991058073780224