Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to Ceramic
Abstract: This study investigated the influence of water storage (24 h and 6 months), and Transbond XT and Fuji Ortho LC bonding materials on the bond strength of metallic brackets bonded to feldspathic ceramic. Four cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Each cylinder received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT or Fuji Ortho LC. Light-activation was carried out with 40 s total exposure time using Bluephase G2. Half the specimens for each bonding materials (n=20) were stored in distilled water at 37 °C for 24 h and the other half for 6 months. Shear bond strength testing was performed after storage times at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the ceramic surface at ×8 magnification. Data were subjected to two-way ANOVA and Tukey's test (p<0.05). Transbond XT showed significantly higher bond strength (p<0.05) than Fuji Ortho LC. Significant differences in bond strength (p<0.05) were found when 24 h and 6 months storage times were compared between materials. ARI showed a predominance of score 0 for all groups, and higher scores at 1, 2 and 3 for 24 h storage time. In conclusion, storage time and bonding materials showed significant influence on the bond strength of brackets to ceramic.
Main Authors: | , , , , , , , |
---|---|
Format: | Digital revista |
Language: | English |
Published: |
Fundação Odontológica de Ribeirão Preto
2015
|
Online Access: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000500503 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
oai:scielo:S0103-64402015000500503 |
---|---|
record_format |
ojs |
spelling |
oai:scielo:S0103-644020150005005032015-12-03Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to CeramicCosta,Ana RosaCorrer,Américo BortolazzoConsani,SimonidesGiorgi,Maria Cecília CaldasVedovello,Silvia AméliaVedovello Filho,MárioSantos,Eduardo Cesar AlmadaCorrer-Sobrinho,Lourenço shear bond strength orthodontic bracket ceramic bonding storage time. Abstract: This study investigated the influence of water storage (24 h and 6 months), and Transbond XT and Fuji Ortho LC bonding materials on the bond strength of metallic brackets bonded to feldspathic ceramic. Four cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Each cylinder received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT or Fuji Ortho LC. Light-activation was carried out with 40 s total exposure time using Bluephase G2. Half the specimens for each bonding materials (n=20) were stored in distilled water at 37 °C for 24 h and the other half for 6 months. Shear bond strength testing was performed after storage times at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the ceramic surface at ×8 magnification. Data were subjected to two-way ANOVA and Tukey's test (p<0.05). Transbond XT showed significantly higher bond strength (p<0.05) than Fuji Ortho LC. Significant differences in bond strength (p<0.05) were found when 24 h and 6 months storage times were compared between materials. ARI showed a predominance of score 0 for all groups, and higher scores at 1, 2 and 3 for 24 h storage time. In conclusion, storage time and bonding materials showed significant influence on the bond strength of brackets to ceramic.info:eu-repo/semantics/openAccessFundação Odontológica de Ribeirão PretoBrazilian Dental Journal v.26 n.5 20152015-10-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000500503en10.1590/0103-6440201300403 |
institution |
SCIELO |
collection |
OJS |
country |
Brasil |
countrycode |
BR |
component |
Revista |
access |
En linea |
databasecode |
rev-scielo-br |
tag |
revista |
region |
America del Sur |
libraryname |
SciELO |
language |
English |
format |
Digital |
author |
Costa,Ana Rosa Correr,Américo Bortolazzo Consani,Simonides Giorgi,Maria Cecília Caldas Vedovello,Silvia Amélia Vedovello Filho,Mário Santos,Eduardo Cesar Almada Correr-Sobrinho,Lourenço |
spellingShingle |
Costa,Ana Rosa Correr,Américo Bortolazzo Consani,Simonides Giorgi,Maria Cecília Caldas Vedovello,Silvia Amélia Vedovello Filho,Mário Santos,Eduardo Cesar Almada Correr-Sobrinho,Lourenço Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to Ceramic |
author_facet |
Costa,Ana Rosa Correr,Américo Bortolazzo Consani,Simonides Giorgi,Maria Cecília Caldas Vedovello,Silvia Amélia Vedovello Filho,Mário Santos,Eduardo Cesar Almada Correr-Sobrinho,Lourenço |
author_sort |
Costa,Ana Rosa |
title |
Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to Ceramic |
title_short |
Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to Ceramic |
title_full |
Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to Ceramic |
title_fullStr |
Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to Ceramic |
title_full_unstemmed |
Influence of Water Storage and Bonding Material on Bond Strength of Metallic Brackets to Ceramic |
title_sort |
influence of water storage and bonding material on bond strength of metallic brackets to ceramic |
description |
Abstract: This study investigated the influence of water storage (24 h and 6 months), and Transbond XT and Fuji Ortho LC bonding materials on the bond strength of metallic brackets bonded to feldspathic ceramic. Four cylinders of feldspathic ceramic were etched with 10% hydrofluoric acid for 60 s. Each cylinder received two layers of silane. Metallic brackets were bonded to the cylinders using Transbond XT or Fuji Ortho LC. Light-activation was carried out with 40 s total exposure time using Bluephase G2. Half the specimens for each bonding materials (n=20) were stored in distilled water at 37 °C for 24 h and the other half for 6 months. Shear bond strength testing was performed after storage times at a crosshead speed of 1 mm/min. The adhesive remnant index (ARI) was used to evaluate the amount of adhesive remaining on the ceramic surface at ×8 magnification. Data were subjected to two-way ANOVA and Tukey's test (p<0.05). Transbond XT showed significantly higher bond strength (p<0.05) than Fuji Ortho LC. Significant differences in bond strength (p<0.05) were found when 24 h and 6 months storage times were compared between materials. ARI showed a predominance of score 0 for all groups, and higher scores at 1, 2 and 3 for 24 h storage time. In conclusion, storage time and bonding materials showed significant influence on the bond strength of brackets to ceramic. |
publisher |
Fundação Odontológica de Ribeirão Preto |
publishDate |
2015 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000500503 |
work_keys_str_mv |
AT costaanarosa influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic AT correramericobortolazzo influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic AT consanisimonides influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic AT giorgimariaceciliacaldas influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic AT vedovellosilviaamelia influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic AT vedovellofilhomario influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic AT santoseduardocesaralmada influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic AT corrersobrinholourenco influenceofwaterstorageandbondingmaterialonbondstrengthofmetallicbracketstoceramic |
_version_ |
1756404564067614720 |