Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MS

A fast and sensitive method using high performance liquid chromatography-fluorescence detection (HPLC-FD) and ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed and validated for the determination of avermectins residues in ovine muscle samples. QuEChERS (quick, easy, cheap, effective, rugged and safe) sample preparation based on acetonitrile extraction followed by partitioning with NaCl and Na2SO4 and dispersive solid-phase extraction (d-SPE) clean-up with C18 was applied. Na2SO4 was used instead of MgSO4 due to lower amounts of co-extractives in the final extract. The procedure was validated according to the Commission Decision 2002/657/EC. The method showed determination coefficients (r2) higher than 0.99, recoveries between 93.2 and 124.3% for spike levels between 0.5 and 2.0 times the maximum residues limit (MRL) values. The repeatability and intermediate precision RSD values ranged from 1 to 19%. Decision limits (CCα) and detection capabilities (CCβ) ranged from 10.7 to 59.4 µg kg-1 and 11.4 to 68.8 µg kg-1, respectively. Method performance was successfully evaluated by analyzing real samples and proficiency test with a z-score in the range of ±1.

Saved in:
Bibliographic Details
Main Authors: Bandeira,Nelson M. G., Ribeiro,Lucila C., Rizzetti,Tiele M., Martins,Manoel L., Adaime,Martha B., Zanella,Renato, Prestes,Osmar D.
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Química 2017
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017000500878
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0103-50532017000500878
record_format ojs
spelling oai:scielo:S0103-505320170005008782017-04-12Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MSBandeira,Nelson M. G.Ribeiro,Lucila C.Rizzetti,Tiele M.Martins,Manoel L.Adaime,Martha B.Zanella,RenatoPrestes,Osmar D. veterinary drugs residue liquid chromatography animal tissue A fast and sensitive method using high performance liquid chromatography-fluorescence detection (HPLC-FD) and ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed and validated for the determination of avermectins residues in ovine muscle samples. QuEChERS (quick, easy, cheap, effective, rugged and safe) sample preparation based on acetonitrile extraction followed by partitioning with NaCl and Na2SO4 and dispersive solid-phase extraction (d-SPE) clean-up with C18 was applied. Na2SO4 was used instead of MgSO4 due to lower amounts of co-extractives in the final extract. The procedure was validated according to the Commission Decision 2002/657/EC. The method showed determination coefficients (r2) higher than 0.99, recoveries between 93.2 and 124.3% for spike levels between 0.5 and 2.0 times the maximum residues limit (MRL) values. The repeatability and intermediate precision RSD values ranged from 1 to 19%. Decision limits (CCα) and detection capabilities (CCβ) ranged from 10.7 to 59.4 µg kg-1 and 11.4 to 68.8 µg kg-1, respectively. Method performance was successfully evaluated by analyzing real samples and proficiency test with a z-score in the range of ±1.info:eu-repo/semantics/openAccessSociedade Brasileira de QuímicaJournal of the Brazilian Chemical Society v.28 n.5 20172017-05-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017000500878en10.21577/0103-5053.20160240
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Bandeira,Nelson M. G.
Ribeiro,Lucila C.
Rizzetti,Tiele M.
Martins,Manoel L.
Adaime,Martha B.
Zanella,Renato
Prestes,Osmar D.
spellingShingle Bandeira,Nelson M. G.
Ribeiro,Lucila C.
Rizzetti,Tiele M.
Martins,Manoel L.
Adaime,Martha B.
Zanella,Renato
Prestes,Osmar D.
Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MS
author_facet Bandeira,Nelson M. G.
Ribeiro,Lucila C.
Rizzetti,Tiele M.
Martins,Manoel L.
Adaime,Martha B.
Zanella,Renato
Prestes,Osmar D.
author_sort Bandeira,Nelson M. G.
title Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MS
title_short Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MS
title_full Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MS
title_fullStr Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MS
title_full_unstemmed Evaluation of QuEChERS Sample Preparation for Determination of Avermectins Residues in Ovine Muscle by HPLC-FD and UHPLC-MS/MS
title_sort evaluation of quechers sample preparation for determination of avermectins residues in ovine muscle by hplc-fd and uhplc-ms/ms
description A fast and sensitive method using high performance liquid chromatography-fluorescence detection (HPLC-FD) and ultra-high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) was developed and validated for the determination of avermectins residues in ovine muscle samples. QuEChERS (quick, easy, cheap, effective, rugged and safe) sample preparation based on acetonitrile extraction followed by partitioning with NaCl and Na2SO4 and dispersive solid-phase extraction (d-SPE) clean-up with C18 was applied. Na2SO4 was used instead of MgSO4 due to lower amounts of co-extractives in the final extract. The procedure was validated according to the Commission Decision 2002/657/EC. The method showed determination coefficients (r2) higher than 0.99, recoveries between 93.2 and 124.3% for spike levels between 0.5 and 2.0 times the maximum residues limit (MRL) values. The repeatability and intermediate precision RSD values ranged from 1 to 19%. Decision limits (CCα) and detection capabilities (CCβ) ranged from 10.7 to 59.4 µg kg-1 and 11.4 to 68.8 µg kg-1, respectively. Method performance was successfully evaluated by analyzing real samples and proficiency test with a z-score in the range of ±1.
publisher Sociedade Brasileira de Química
publishDate 2017
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532017000500878
work_keys_str_mv AT bandeiranelsonmg evaluationofquecherssamplepreparationfordeterminationofavermectinsresiduesinovinemusclebyhplcfdanduhplcmsms
AT ribeirolucilac evaluationofquecherssamplepreparationfordeterminationofavermectinsresiduesinovinemusclebyhplcfdanduhplcmsms
AT rizzettitielem evaluationofquecherssamplepreparationfordeterminationofavermectinsresiduesinovinemusclebyhplcfdanduhplcmsms
AT martinsmanoell evaluationofquecherssamplepreparationfordeterminationofavermectinsresiduesinovinemusclebyhplcfdanduhplcmsms
AT adaimemarthab evaluationofquecherssamplepreparationfordeterminationofavermectinsresiduesinovinemusclebyhplcfdanduhplcmsms
AT zanellarenato evaluationofquecherssamplepreparationfordeterminationofavermectinsresiduesinovinemusclebyhplcfdanduhplcmsms
AT prestesosmard evaluationofquecherssamplepreparationfordeterminationofavermectinsresiduesinovinemusclebyhplcfdanduhplcmsms
_version_ 1756403683840491520