Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applications

An isocratic reversed phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the determination of gemifloxacin in bulk, dosage formulations and human serum at 270 nm. Chromatographic separation was achieved on Purospher STAR C18 (250 × 4.6 mm, 5 µm) column using mobile phase methanol:water (90:10, v/v) adjusted pH 2.8 via phosphoric acid 85% having flow rate of 1.5 mL min-1 at ambient temperature. Calibration curves were linear over range of 5-100 µg mL-1 with a correlation coefficient 0.9998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.015 and 0.045 µg mL-1, respectively. Intra and inter-run precision and accuracy results were 98.73-100.12% and then correlated through student'st-test. This method was further applied for in vitro interactions of gemifloxacin with essential and trace elements.

Saved in:
Bibliographic Details
Main Authors: Sultana,Najma, Arayne,M. Saeed, Shamim,Sana, Akhtar,Mahwish, Gul,Somia
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Química 2011
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011000500024
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0103-50532011000500024
record_format ojs
spelling oai:scielo:S0103-505320110005000242011-05-16Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applicationsSultana,NajmaArayne,M. SaeedShamim,SanaAkhtar,MahwishGul,Somia gemifloxacin HPLC human serum student's t-test An isocratic reversed phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the determination of gemifloxacin in bulk, dosage formulations and human serum at 270 nm. Chromatographic separation was achieved on Purospher STAR C18 (250 × 4.6 mm, 5 µm) column using mobile phase methanol:water (90:10, v/v) adjusted pH 2.8 via phosphoric acid 85% having flow rate of 1.5 mL min-1 at ambient temperature. Calibration curves were linear over range of 5-100 µg mL-1 with a correlation coefficient 0.9998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.015 and 0.045 µg mL-1, respectively. Intra and inter-run precision and accuracy results were 98.73-100.12% and then correlated through student'st-test. This method was further applied for in vitro interactions of gemifloxacin with essential and trace elements.info:eu-repo/semantics/openAccessSociedade Brasileira de QuímicaJournal of the Brazilian Chemical Society v.22 n.5 20112011-05-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011000500024en10.1590/S0103-50532011000500024
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Sultana,Najma
Arayne,M. Saeed
Shamim,Sana
Akhtar,Mahwish
Gul,Somia
spellingShingle Sultana,Najma
Arayne,M. Saeed
Shamim,Sana
Akhtar,Mahwish
Gul,Somia
Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applications
author_facet Sultana,Najma
Arayne,M. Saeed
Shamim,Sana
Akhtar,Mahwish
Gul,Somia
author_sort Sultana,Najma
title Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applications
title_short Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applications
title_full Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applications
title_fullStr Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applications
title_full_unstemmed Validated method for the determination of Gemifloxacin in bulk, pharmaceutical formulations and human serum by RP-HPLC: in vitro applications
title_sort validated method for the determination of gemifloxacin in bulk, pharmaceutical formulations and human serum by rp-hplc: in vitro applications
description An isocratic reversed phase high-performance liquid chromatographic (RP-HPLC) method has been developed for the determination of gemifloxacin in bulk, dosage formulations and human serum at 270 nm. Chromatographic separation was achieved on Purospher STAR C18 (250 × 4.6 mm, 5 µm) column using mobile phase methanol:water (90:10, v/v) adjusted pH 2.8 via phosphoric acid 85% having flow rate of 1.5 mL min-1 at ambient temperature. Calibration curves were linear over range of 5-100 µg mL-1 with a correlation coefficient 0.9998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.015 and 0.045 µg mL-1, respectively. Intra and inter-run precision and accuracy results were 98.73-100.12% and then correlated through student'st-test. This method was further applied for in vitro interactions of gemifloxacin with essential and trace elements.
publisher Sociedade Brasileira de Química
publishDate 2011
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532011000500024
work_keys_str_mv AT sultananajma validatedmethodforthedeterminationofgemifloxacininbulkpharmaceuticalformulationsandhumanserumbyrphplcinvitroapplications
AT araynemsaeed validatedmethodforthedeterminationofgemifloxacininbulkpharmaceuticalformulationsandhumanserumbyrphplcinvitroapplications
AT shamimsana validatedmethodforthedeterminationofgemifloxacininbulkpharmaceuticalformulationsandhumanserumbyrphplcinvitroapplications
AT akhtarmahwish validatedmethodforthedeterminationofgemifloxacininbulkpharmaceuticalformulationsandhumanserumbyrphplcinvitroapplications
AT gulsomia validatedmethodforthedeterminationofgemifloxacininbulkpharmaceuticalformulationsandhumanserumbyrphplcinvitroapplications
_version_ 1756403436053594112