Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trial

ABSTRACT PURPOSE To evaluate the safety and efficacy of a new mesh in the pre-peritoneal repair of inguinal hernia. METHODS We randomly divided 120 patients undergoing pre-peritoneal repair into 2 groups between March 2012 and December 2013. The patients were randomized to receive the Swing mesh (n=60; study group) or the Modified Kugel mesh (n=60; control group). The primary end point of this study was to compare postoperative groin pain of the two groups. Complications, recurrence and analgesic use were also recorded. RESULTS There were no recurrent cases in either group throughout the study period. There was no significant difference between the groups with respect to postoperative complications. The VAS of early postoperative pain was 1.32±1.69 in study group and 1.52±1.93 in control group, with the difference being not statistically significant (p = 0.547). Concerning chronic pain, no remarkable statistically significant difference was observed between the two groups at 3-month, 6-month, 12- and 18-month follow-up period. CONCLUSION Swing mesh can be safely and effectively used in inguinal hernia repair with the same advantage compared to the Modified Kugel mesh.

Saved in:
Bibliographic Details
Main Authors: Zhou,Zhiyuan, Hu,Xingchen, Zhang,Beili, Gu,Yan
Format: Digital revista
Language:English
Published: Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia 2016
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016001200834
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0102-86502016001200834
record_format ojs
spelling oai:scielo:S0102-865020160012008342017-01-06Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trialZhou,ZhiyuanHu,XingchenZhang,BeiliGu,Yan Hernia Inguinal Surgical Mesh ABSTRACT PURPOSE To evaluate the safety and efficacy of a new mesh in the pre-peritoneal repair of inguinal hernia. METHODS We randomly divided 120 patients undergoing pre-peritoneal repair into 2 groups between March 2012 and December 2013. The patients were randomized to receive the Swing mesh (n=60; study group) or the Modified Kugel mesh (n=60; control group). The primary end point of this study was to compare postoperative groin pain of the two groups. Complications, recurrence and analgesic use were also recorded. RESULTS There were no recurrent cases in either group throughout the study period. There was no significant difference between the groups with respect to postoperative complications. The VAS of early postoperative pain was 1.32±1.69 in study group and 1.52±1.93 in control group, with the difference being not statistically significant (p = 0.547). Concerning chronic pain, no remarkable statistically significant difference was observed between the two groups at 3-month, 6-month, 12- and 18-month follow-up period. CONCLUSION Swing mesh can be safely and effectively used in inguinal hernia repair with the same advantage compared to the Modified Kugel mesh.info:eu-repo/semantics/openAccessSociedade Brasileira para o Desenvolvimento da Pesquisa em CirurgiaActa Cirúrgica Brasileira v.31 n.12 20162016-12-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016001200834en10.1590/s0102-865020160120000009
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Zhou,Zhiyuan
Hu,Xingchen
Zhang,Beili
Gu,Yan
spellingShingle Zhou,Zhiyuan
Hu,Xingchen
Zhang,Beili
Gu,Yan
Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trial
author_facet Zhou,Zhiyuan
Hu,Xingchen
Zhang,Beili
Gu,Yan
author_sort Zhou,Zhiyuan
title Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trial
title_short Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trial
title_full Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trial
title_fullStr Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trial
title_full_unstemmed Swing mesh versus Modified Kugel mesh for primary inguinal hernia repair. A prospective randomized clinical trial
title_sort swing mesh versus modified kugel mesh for primary inguinal hernia repair. a prospective randomized clinical trial
description ABSTRACT PURPOSE To evaluate the safety and efficacy of a new mesh in the pre-peritoneal repair of inguinal hernia. METHODS We randomly divided 120 patients undergoing pre-peritoneal repair into 2 groups between March 2012 and December 2013. The patients were randomized to receive the Swing mesh (n=60; study group) or the Modified Kugel mesh (n=60; control group). The primary end point of this study was to compare postoperative groin pain of the two groups. Complications, recurrence and analgesic use were also recorded. RESULTS There were no recurrent cases in either group throughout the study period. There was no significant difference between the groups with respect to postoperative complications. The VAS of early postoperative pain was 1.32±1.69 in study group and 1.52±1.93 in control group, with the difference being not statistically significant (p = 0.547). Concerning chronic pain, no remarkable statistically significant difference was observed between the two groups at 3-month, 6-month, 12- and 18-month follow-up period. CONCLUSION Swing mesh can be safely and effectively used in inguinal hernia repair with the same advantage compared to the Modified Kugel mesh.
publisher Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia
publishDate 2016
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-86502016001200834
work_keys_str_mv AT zhouzhiyuan swingmeshversusmodifiedkugelmeshforprimaryinguinalherniarepairaprospectiverandomizedclinicaltrial
AT huxingchen swingmeshversusmodifiedkugelmeshforprimaryinguinalherniarepairaprospectiverandomizedclinicaltrial
AT zhangbeili swingmeshversusmodifiedkugelmeshforprimaryinguinalherniarepairaprospectiverandomizedclinicaltrial
AT guyan swingmeshversusmodifiedkugelmeshforprimaryinguinalherniarepairaprospectiverandomizedclinicaltrial
_version_ 1756400998421626880