Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral Nails

Abstract Objective The present study aims to identify the energy required for synthetic proximal femoral fracture after removal of three implant types: cannulated screws, dynamic hip screws (DHS), and proximal femoral nail (PFN). Methods Twenty-five synthetic proximal femur bones were used: 10 were kept intact as the control group (CG), 5 were submitted to the placement and removal of 3 cannulated screws in an inverted triangle configuration (CSG), 5 were submitted to the placement and removal of a dynamic compression screw (DHSG), and 5 were submitted to the placement and removal of a proximal femur nail (PFNG). All samples were biomechanically analyzed simulating a fall on the greater trochanter using a servo-hydraulic machine to determine the energy (in Joules [J]) required for fracture. Results All samples presented basicervical fractures. The energy required for fracture was 7.1 J, 6.6 J, 6 J, and 6.7 J for the CG, CSG, DHSG and PFNG, respectively. There was no statistically significant difference (considering a 95% confidence interval) in energy among the study groups (p = 0.34). Conclusion There was no statistically significant difference in the energy required to cause a synthetic proximal femoral fracture after removing all three implant types and simulating a fall over the greater trochanter.

Saved in:
Bibliographic Details
Main Authors: Freitas,Anderson, Silva,Landwehrle de Lucena da, Costa,Renilton Rodrigues, Ramos,Lucas Sacramento, Giordano,Marcos Norberto, Gonçalves,Henrique Mansur
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Ortopedia e Traumatologia 2021
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162021000200251
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0102-36162021000200251
record_format ojs
spelling oai:scielo:S0102-361620210002002512021-05-31Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral NailsFreitas,AndersonSilva,Landwehrle de Lucena daCosta,Renilton RodriguesRamos,Lucas SacramentoGiordano,Marcos NorbertoGonçalves,Henrique Mansur hip hip fractures fracture fixation device removal Abstract Objective The present study aims to identify the energy required for synthetic proximal femoral fracture after removal of three implant types: cannulated screws, dynamic hip screws (DHS), and proximal femoral nail (PFN). Methods Twenty-five synthetic proximal femur bones were used: 10 were kept intact as the control group (CG), 5 were submitted to the placement and removal of 3 cannulated screws in an inverted triangle configuration (CSG), 5 were submitted to the placement and removal of a dynamic compression screw (DHSG), and 5 were submitted to the placement and removal of a proximal femur nail (PFNG). All samples were biomechanically analyzed simulating a fall on the greater trochanter using a servo-hydraulic machine to determine the energy (in Joules [J]) required for fracture. Results All samples presented basicervical fractures. The energy required for fracture was 7.1 J, 6.6 J, 6 J, and 6.7 J for the CG, CSG, DHSG and PFNG, respectively. There was no statistically significant difference (considering a 95% confidence interval) in energy among the study groups (p = 0.34). Conclusion There was no statistically significant difference in the energy required to cause a synthetic proximal femoral fracture after removing all three implant types and simulating a fall over the greater trochanter.info:eu-repo/semantics/openAccessSociedade Brasileira de Ortopedia e TraumatologiaRevista Brasileira de Ortopedia v.56 n.2 20212021-04-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162021000200251en10.1055/s-0040-1721832
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Freitas,Anderson
Silva,Landwehrle de Lucena da
Costa,Renilton Rodrigues
Ramos,Lucas Sacramento
Giordano,Marcos Norberto
Gonçalves,Henrique Mansur
spellingShingle Freitas,Anderson
Silva,Landwehrle de Lucena da
Costa,Renilton Rodrigues
Ramos,Lucas Sacramento
Giordano,Marcos Norberto
Gonçalves,Henrique Mansur
Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral Nails
author_facet Freitas,Anderson
Silva,Landwehrle de Lucena da
Costa,Renilton Rodrigues
Ramos,Lucas Sacramento
Giordano,Marcos Norberto
Gonçalves,Henrique Mansur
author_sort Freitas,Anderson
title Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral Nails
title_short Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral Nails
title_full Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral Nails
title_fullStr Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral Nails
title_full_unstemmed Energy Required for Fracture in Synthetic Proximal Femoral Models After Synthesis Material Removal: a Biomechanical Study Using Cannulated Screws, Dynamic Hip Screws, and Proximal Femoral Nails
title_sort energy required for fracture in synthetic proximal femoral models after synthesis material removal: a biomechanical study using cannulated screws, dynamic hip screws, and proximal femoral nails
description Abstract Objective The present study aims to identify the energy required for synthetic proximal femoral fracture after removal of three implant types: cannulated screws, dynamic hip screws (DHS), and proximal femoral nail (PFN). Methods Twenty-five synthetic proximal femur bones were used: 10 were kept intact as the control group (CG), 5 were submitted to the placement and removal of 3 cannulated screws in an inverted triangle configuration (CSG), 5 were submitted to the placement and removal of a dynamic compression screw (DHSG), and 5 were submitted to the placement and removal of a proximal femur nail (PFNG). All samples were biomechanically analyzed simulating a fall on the greater trochanter using a servo-hydraulic machine to determine the energy (in Joules [J]) required for fracture. Results All samples presented basicervical fractures. The energy required for fracture was 7.1 J, 6.6 J, 6 J, and 6.7 J for the CG, CSG, DHSG and PFNG, respectively. There was no statistically significant difference (considering a 95% confidence interval) in energy among the study groups (p = 0.34). Conclusion There was no statistically significant difference in the energy required to cause a synthetic proximal femoral fracture after removing all three implant types and simulating a fall over the greater trochanter.
publisher Sociedade Brasileira de Ortopedia e Traumatologia
publishDate 2021
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-36162021000200251
work_keys_str_mv AT freitasanderson energyrequiredforfractureinsyntheticproximalfemoralmodelsaftersynthesismaterialremovalabiomechanicalstudyusingcannulatedscrewsdynamichipscrewsandproximalfemoralnails
AT silvalandwehrledelucenada energyrequiredforfractureinsyntheticproximalfemoralmodelsaftersynthesismaterialremovalabiomechanicalstudyusingcannulatedscrewsdynamichipscrewsandproximalfemoralnails
AT costareniltonrodrigues energyrequiredforfractureinsyntheticproximalfemoralmodelsaftersynthesismaterialremovalabiomechanicalstudyusingcannulatedscrewsdynamichipscrewsandproximalfemoralnails
AT ramoslucassacramento energyrequiredforfractureinsyntheticproximalfemoralmodelsaftersynthesismaterialremovalabiomechanicalstudyusingcannulatedscrewsdynamichipscrewsandproximalfemoralnails
AT giordanomarcosnorberto energyrequiredforfractureinsyntheticproximalfemoralmodelsaftersynthesismaterialremovalabiomechanicalstudyusingcannulatedscrewsdynamichipscrewsandproximalfemoralnails
AT goncalveshenriquemansur energyrequiredforfractureinsyntheticproximalfemoralmodelsaftersynthesismaterialremovalabiomechanicalstudyusingcannulatedscrewsdynamichipscrewsandproximalfemoralnails
_version_ 1756397839532949504