Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies

A chromatographic technique for determination of rutin and narcissin in marigold extract and topical formulations was developed and validated. The method shows linearity over the concentration range of 0.2 - 6.0 μg/mL of rutin (r = 0.9986) and 0.8 - 12.0 μg/mL of narcissin (r = 0.9951). The values obtained for precision and accuracy are in agreement with ICH guidelines. Both the formulation excipients and the porcine ear skin samples did not interfere with the flavonoids determination. The recovery of rutin and narcissin in skin samples added with marigold extract was 81.41% and 83.35%, respectively, which demonstrate the applicability of this method to perform skin penetration studies.

Saved in:
Bibliographic Details
Main Authors: Fonseca,Yris Maria, Vicentini,Fabiana T. M. C., Catini,Carolina Dias, Fonseca,Maria José Vieira
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Química 2010
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000600019
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0100-40422010000600019
record_format ojs
spelling oai:scielo:S0100-404220100006000192010-08-24Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studiesFonseca,Yris MariaVicentini,Fabiana T. M. C.Catini,Carolina DiasFonseca,Maria José Vieira Calendula officinalis narcissin rutin A chromatographic technique for determination of rutin and narcissin in marigold extract and topical formulations was developed and validated. The method shows linearity over the concentration range of 0.2 - 6.0 μg/mL of rutin (r = 0.9986) and 0.8 - 12.0 μg/mL of narcissin (r = 0.9951). The values obtained for precision and accuracy are in agreement with ICH guidelines. Both the formulation excipients and the porcine ear skin samples did not interfere with the flavonoids determination. The recovery of rutin and narcissin in skin samples added with marigold extract was 81.41% and 83.35%, respectively, which demonstrate the applicability of this method to perform skin penetration studies.info:eu-repo/semantics/openAccessSociedade Brasileira de QuímicaQuímica Nova v.33 n.6 20102010-01-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000600019en10.1590/S0100-40422010000600019
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Fonseca,Yris Maria
Vicentini,Fabiana T. M. C.
Catini,Carolina Dias
Fonseca,Maria José Vieira
spellingShingle Fonseca,Yris Maria
Vicentini,Fabiana T. M. C.
Catini,Carolina Dias
Fonseca,Maria José Vieira
Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies
author_facet Fonseca,Yris Maria
Vicentini,Fabiana T. M. C.
Catini,Carolina Dias
Fonseca,Maria José Vieira
author_sort Fonseca,Yris Maria
title Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies
title_short Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies
title_full Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies
title_fullStr Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies
title_full_unstemmed Determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies
title_sort determination of rutin and narcissin in marigold extract and topical formulations by liquid chromatography: applicability in skin penetration studies
description A chromatographic technique for determination of rutin and narcissin in marigold extract and topical formulations was developed and validated. The method shows linearity over the concentration range of 0.2 - 6.0 μg/mL of rutin (r = 0.9986) and 0.8 - 12.0 μg/mL of narcissin (r = 0.9951). The values obtained for precision and accuracy are in agreement with ICH guidelines. Both the formulation excipients and the porcine ear skin samples did not interfere with the flavonoids determination. The recovery of rutin and narcissin in skin samples added with marigold extract was 81.41% and 83.35%, respectively, which demonstrate the applicability of this method to perform skin penetration studies.
publisher Sociedade Brasileira de Química
publishDate 2010
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422010000600019
work_keys_str_mv AT fonsecayrismaria determinationofrutinandnarcissininmarigoldextractandtopicalformulationsbyliquidchromatographyapplicabilityinskinpenetrationstudies
AT vicentinifabianatmc determinationofrutinandnarcissininmarigoldextractandtopicalformulationsbyliquidchromatographyapplicabilityinskinpenetrationstudies
AT catinicarolinadias determinationofrutinandnarcissininmarigoldextractandtopicalformulationsbyliquidchromatographyapplicabilityinskinpenetrationstudies
AT fonsecamariajosevieira determinationofrutinandnarcissininmarigoldextractandtopicalformulationsbyliquidchromatographyapplicabilityinskinpenetrationstudies
_version_ 1756387387133394944