The role of stereoradiography in the evaluation of lower limb deformities

Abstract Deformities of the lower limbs are a common condition and can lead to changes in gait, as well as affecting the function and longevity of the hips, knees, and spine. A systematic approach is essential to achieve the desired therapeutic result with the lowest rate of complications. Panoramic radiography is a widely available, low-cost method that is commonly used in order to assess the length and angular deformities of the lower limbs, by measuring the length and angular deviations of the axes. However, because the combination of lower limb deformities in two or three orthogonal planes is common, conventional radiography lacks accuracy because it is a two-dimensional imaging method. Therefore, the measurements of valgus/varus deformities on X-rays restricted to the coronal plane will present increasing variations in measurements depending on the degree of flexion/recurvatum alignment, anomalous bone torsions, or, last but not least, inappropriate patient positioning. Low-dose biplanar stereoradiography using three-dimensional models increases the accuracy of the measurement of several parameters used in the evaluation of lower limb alignment, including lengths, axes, and tibial/femoral torsions, parameters that could previously be evaluated only by computed tomography. Stereoradiography also makes it possible to perform a head-to-toe evaluation, as well as to evaluate the interactions among the lower limbs, pelvis, and spine.

Saved in:
Bibliographic Details
Main Authors: Silva,Flávio Duarte, Chemin,Renan Nogueira, Ormond Filho,Alípio Gomes, Guimarães,Júlio Brandão, Zorzenoni,Fernando Ometto, Nico,Marcelo Astolfi Caetano
Format: Digital revista
Language:English
Published: Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem 2022
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000200104
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0100-39842022000200104
record_format ojs
spelling oai:scielo:S0100-398420220002001042022-05-20The role of stereoradiography in the evaluation of lower limb deformitiesSilva,Flávio DuarteChemin,Renan NogueiraOrmond Filho,Alípio GomesGuimarães,Júlio BrandãoZorzenoni,Fernando OmettoNico,Marcelo Astolfi Caetano Radiography Lower limb Lower extremity deformities Diagnostic imaging Abstract Deformities of the lower limbs are a common condition and can lead to changes in gait, as well as affecting the function and longevity of the hips, knees, and spine. A systematic approach is essential to achieve the desired therapeutic result with the lowest rate of complications. Panoramic radiography is a widely available, low-cost method that is commonly used in order to assess the length and angular deformities of the lower limbs, by measuring the length and angular deviations of the axes. However, because the combination of lower limb deformities in two or three orthogonal planes is common, conventional radiography lacks accuracy because it is a two-dimensional imaging method. Therefore, the measurements of valgus/varus deformities on X-rays restricted to the coronal plane will present increasing variations in measurements depending on the degree of flexion/recurvatum alignment, anomalous bone torsions, or, last but not least, inappropriate patient positioning. Low-dose biplanar stereoradiography using three-dimensional models increases the accuracy of the measurement of several parameters used in the evaluation of lower limb alignment, including lengths, axes, and tibial/femoral torsions, parameters that could previously be evaluated only by computed tomography. Stereoradiography also makes it possible to perform a head-to-toe evaluation, as well as to evaluate the interactions among the lower limbs, pelvis, and spine.info:eu-repo/semantics/openAccessPublicação do Colégio Brasileiro de Radiologia e Diagnóstico por ImagemRadiologia Brasileira v.55 n.2 20222022-03-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000200104en10.1590/0100-3984.2021.0104
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Silva,Flávio Duarte
Chemin,Renan Nogueira
Ormond Filho,Alípio Gomes
Guimarães,Júlio Brandão
Zorzenoni,Fernando Ometto
Nico,Marcelo Astolfi Caetano
spellingShingle Silva,Flávio Duarte
Chemin,Renan Nogueira
Ormond Filho,Alípio Gomes
Guimarães,Júlio Brandão
Zorzenoni,Fernando Ometto
Nico,Marcelo Astolfi Caetano
The role of stereoradiography in the evaluation of lower limb deformities
author_facet Silva,Flávio Duarte
Chemin,Renan Nogueira
Ormond Filho,Alípio Gomes
Guimarães,Júlio Brandão
Zorzenoni,Fernando Ometto
Nico,Marcelo Astolfi Caetano
author_sort Silva,Flávio Duarte
title The role of stereoradiography in the evaluation of lower limb deformities
title_short The role of stereoradiography in the evaluation of lower limb deformities
title_full The role of stereoradiography in the evaluation of lower limb deformities
title_fullStr The role of stereoradiography in the evaluation of lower limb deformities
title_full_unstemmed The role of stereoradiography in the evaluation of lower limb deformities
title_sort role of stereoradiography in the evaluation of lower limb deformities
description Abstract Deformities of the lower limbs are a common condition and can lead to changes in gait, as well as affecting the function and longevity of the hips, knees, and spine. A systematic approach is essential to achieve the desired therapeutic result with the lowest rate of complications. Panoramic radiography is a widely available, low-cost method that is commonly used in order to assess the length and angular deformities of the lower limbs, by measuring the length and angular deviations of the axes. However, because the combination of lower limb deformities in two or three orthogonal planes is common, conventional radiography lacks accuracy because it is a two-dimensional imaging method. Therefore, the measurements of valgus/varus deformities on X-rays restricted to the coronal plane will present increasing variations in measurements depending on the degree of flexion/recurvatum alignment, anomalous bone torsions, or, last but not least, inappropriate patient positioning. Low-dose biplanar stereoradiography using three-dimensional models increases the accuracy of the measurement of several parameters used in the evaluation of lower limb alignment, including lengths, axes, and tibial/femoral torsions, parameters that could previously be evaluated only by computed tomography. Stereoradiography also makes it possible to perform a head-to-toe evaluation, as well as to evaluate the interactions among the lower limbs, pelvis, and spine.
publisher Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
publishDate 2022
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842022000200104
work_keys_str_mv AT silvaflavioduarte theroleofstereoradiographyintheevaluationoflowerlimbdeformities
AT cheminrenannogueira theroleofstereoradiographyintheevaluationoflowerlimbdeformities
AT ormondfilhoalipiogomes theroleofstereoradiographyintheevaluationoflowerlimbdeformities
AT guimaraesjuliobrandao theroleofstereoradiographyintheevaluationoflowerlimbdeformities
AT zorzenonifernandoometto theroleofstereoradiographyintheevaluationoflowerlimbdeformities
AT nicomarceloastolficaetano theroleofstereoradiographyintheevaluationoflowerlimbdeformities
AT silvaflavioduarte roleofstereoradiographyintheevaluationoflowerlimbdeformities
AT cheminrenannogueira roleofstereoradiographyintheevaluationoflowerlimbdeformities
AT ormondfilhoalipiogomes roleofstereoradiographyintheevaluationoflowerlimbdeformities
AT guimaraesjuliobrandao roleofstereoradiographyintheevaluationoflowerlimbdeformities
AT zorzenonifernandoometto roleofstereoradiographyintheevaluationoflowerlimbdeformities
AT nicomarceloastolficaetano roleofstereoradiographyintheevaluationoflowerlimbdeformities
_version_ 1756386949405343744