Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS

Analysis of several herbicides used to control weeds in forestry (simazine, hexazinone, pendimethalin, and thiazopyr) has been performed by GC-NPD and GC/MS. A method based on the extraction of soil samples in small columns has been used for the determination of these compounds in soil. Acetone/water (9010) was used for the extraction of all four compounds, and ethyl acetate can be used when the determination of hexazinone is not required. The recoveries through the method were always >80%, and the detection limit was <0.01 ppm for GC-NPD and GC/MS. Soil samples from experimental fields, taken at different times after treatment from the plow layer, were analyzed according to this method, and values similar to those obtained by a conventional method using mechanical shaking extraction were obtained.

Saved in:
Bibliographic Details
Main Authors: Pérez Martín, Rosa Ana, Sánchez-Brunete, C., Miguel Gómez, María Esther, Tadeo Lluch, José Luis
Format: artículo biblioteca
Language:English
Published: American Chemical Society 1998
Subjects:Hexazinone, Pendimethalin, Simazine, Thiazopyr, Soil, Extraction,
Online Access:http://hdl.handle.net/20.500.12792/3420
http://hdl.handle.net/10261/290448
Tags: Add Tag
No Tags, Be the first to tag this record!
id dig-inia-es-10261-290448
record_format koha
spelling dig-inia-es-10261-2904482023-02-17T12:25:46Z Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS Pérez Martín, Rosa Ana Sánchez-Brunete, C. Miguel Gómez, María Esther Tadeo Lluch, José Luis Hexazinone Pendimethalin Simazine Thiazopyr Soil Extraction Analysis of several herbicides used to control weeds in forestry (simazine, hexazinone, pendimethalin, and thiazopyr) has been performed by GC-NPD and GC/MS. A method based on the extraction of soil samples in small columns has been used for the determination of these compounds in soil. Acetone/water (9010) was used for the extraction of all four compounds, and ethyl acetate can be used when the determination of hexazinone is not required. The recoveries through the method were always >80%, and the detection limit was <0.01 ppm for GC-NPD and GC/MS. Soil samples from experimental fields, taken at different times after treatment from the plow layer, were analyzed according to this method, and values similar to those obtained by a conventional method using mechanical shaking extraction were obtained. 2023-02-17T12:25:46Z 2023-02-17T12:25:46Z 1998 artículo Journal of Agricultural and Food Chemistry 46(5): 1864-1869 (1998) 0021-8561 http://hdl.handle.net/20.500.12792/3420 http://hdl.handle.net/10261/290448 10.1021/jf970854b 1520-5118 en none American Chemical Society
institution INIA ES
collection DSpace
country España
countrycode ES
component Bibliográfico
access En linea
databasecode dig-inia-es
tag biblioteca
region Europa del Sur
libraryname Biblioteca del INIA España
language English
topic Hexazinone
Pendimethalin
Simazine
Thiazopyr
Soil
Extraction
Hexazinone
Pendimethalin
Simazine
Thiazopyr
Soil
Extraction
spellingShingle Hexazinone
Pendimethalin
Simazine
Thiazopyr
Soil
Extraction
Hexazinone
Pendimethalin
Simazine
Thiazopyr
Soil
Extraction
Pérez Martín, Rosa Ana
Sánchez-Brunete, C.
Miguel Gómez, María Esther
Tadeo Lluch, José Luis
Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS
description Analysis of several herbicides used to control weeds in forestry (simazine, hexazinone, pendimethalin, and thiazopyr) has been performed by GC-NPD and GC/MS. A method based on the extraction of soil samples in small columns has been used for the determination of these compounds in soil. Acetone/water (9010) was used for the extraction of all four compounds, and ethyl acetate can be used when the determination of hexazinone is not required. The recoveries through the method were always >80%, and the detection limit was <0.01 ppm for GC-NPD and GC/MS. Soil samples from experimental fields, taken at different times after treatment from the plow layer, were analyzed according to this method, and values similar to those obtained by a conventional method using mechanical shaking extraction were obtained.
format artículo
topic_facet Hexazinone
Pendimethalin
Simazine
Thiazopyr
Soil
Extraction
author Pérez Martín, Rosa Ana
Sánchez-Brunete, C.
Miguel Gómez, María Esther
Tadeo Lluch, José Luis
author_facet Pérez Martín, Rosa Ana
Sánchez-Brunete, C.
Miguel Gómez, María Esther
Tadeo Lluch, José Luis
author_sort Pérez Martín, Rosa Ana
title Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS
title_short Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS
title_full Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS
title_fullStr Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS
title_full_unstemmed Analytical methods for the determination in soil of herbicides used in forestry by GC-NPD and GC/MS
title_sort analytical methods for the determination in soil of herbicides used in forestry by gc-npd and gc/ms
publisher American Chemical Society
publishDate 1998
url http://hdl.handle.net/20.500.12792/3420
http://hdl.handle.net/10261/290448
work_keys_str_mv AT perezmartinrosaana analyticalmethodsforthedeterminationinsoilofherbicidesusedinforestrybygcnpdandgcms
AT sanchezbrunetec analyticalmethodsforthedeterminationinsoilofherbicidesusedinforestrybygcnpdandgcms
AT miguelgomezmariaesther analyticalmethodsforthedeterminationinsoilofherbicidesusedinforestrybygcnpdandgcms
AT tadeolluchjoseluis analyticalmethodsforthedeterminationinsoilofherbicidesusedinforestrybygcnpdandgcms
_version_ 1767603087833300992