Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples

Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases.The optimization of the LC separation to distinguish all target compounds and their interferences.This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs.

Saved in:
Bibliographic Details
Main Authors: Lorenzo, María, Campo, Julián, Picó, Yolanda
Other Authors: Ministerio de Economía y Competitividad (España)
Format: artículo biblioteca
Published: Elsevier 2016
Subjects:Interferences, LC–MS/MS, Trap column, Water, Organophosphate flame retardants, solid phase extraction,
Online Access:http://hdl.handle.net/10261/141196
http://dx.doi.org/10.13039/501100003329
http://dx.doi.org/10.13039/501100010805
Tags: Add Tag
No Tags, Be the first to tag this record!
id dig-cide-es-10261-141196
record_format koha
spelling dig-cide-es-10261-1411962021-12-27T15:54:01Z Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples Lorenzo, María Campo, Julián Picó, Yolanda Ministerio de Economía y Competitividad (España) Universidad de Valencia Fundación Tatiana Pérez de Guzmán el Bueno Interferences LC–MS/MS Trap column Water Organophosphate flame retardants solid phase extraction Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases.The optimization of the LC separation to distinguish all target compounds and their interferences.This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs. This work has been supported by the Spanish Ministry of Economy and Competitiveness through the projects GCL2011-29703-C02-02 (http://mefturia.es) and GCL2015-64454-C2-1-R (ECO2risk-dds) and the University of Valencia through the project (UV-INV-AE15-348995). María Lorenzo also acknowledges to the Foundation “Tatiana Pérez de Guzmán el Bueno” for the grant to get the PhD. Peer Reviewed 2016-12-07T10:37:54Z 2016-12-07T10:37:54Z 2016 2016-12-07T10:37:55Z artículo http://purl.org/coar/resource_type/c_6501 issn: 2215-0161 MethodsX 3: 343-349 (2016) http://hdl.handle.net/10261/141196 10.1016/j.mex.2016.04.006 http://dx.doi.org/10.13039/501100003329 http://dx.doi.org/10.13039/501100010805 27222824 Postprint https://doi.org/10.1016/j.mex.2016.04.006 Sí open Elsevier
institution CIDE ES
collection DSpace
country España
countrycode ES
component Bibliográfico
access En linea
databasecode dig-cide-es
tag biblioteca
region Europa del Sur
libraryname Biblioteca del CIDE España
topic Interferences
LC–MS/MS
Trap column
Water
Organophosphate flame retardants
solid phase extraction
Interferences
LC–MS/MS
Trap column
Water
Organophosphate flame retardants
solid phase extraction
spellingShingle Interferences
LC–MS/MS
Trap column
Water
Organophosphate flame retardants
solid phase extraction
Interferences
LC–MS/MS
Trap column
Water
Organophosphate flame retardants
solid phase extraction
Lorenzo, María
Campo, Julián
Picó, Yolanda
Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
description Few methods are available for comprehensive organophosphate flame retardants (PFRs) detection in water and wastewater. Gas chromatography has been employed previously, but this approach is less selective, not amenable for use with deuterated standards and can suffer unfavorable fragmentation. Ultra-high-pressure liquid chromatography tandem mass spectrometry (UHPLC-QqQ-MS/MS) has become the most promising platform, already applied successfully for analysis of selected PFRs in some environmental matrices like water and wastewater. However, the presence of some interferences from the dissolvent, the equipment and the used materials should be taken into account. The procedure involves: The first determination of PFRs by UHPLC-QqQ-MS/MS using a trap column to distinguish the interferences coming from the instrument and mobile phases.The optimization of the LC separation to distinguish all target compounds and their interferences.This method coupled to a solid-phase extraction (SPE) improve the detection and quantification of PFRs.
author2 Ministerio de Economía y Competitividad (España)
author_facet Ministerio de Economía y Competitividad (España)
Lorenzo, María
Campo, Julián
Picó, Yolanda
format artículo
topic_facet Interferences
LC–MS/MS
Trap column
Water
Organophosphate flame retardants
solid phase extraction
author Lorenzo, María
Campo, Julián
Picó, Yolanda
author_sort Lorenzo, María
title Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_short Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_full Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_fullStr Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_full_unstemmed Ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
title_sort ultra-high-pressure liquid chromatography tandem mass spectrometry method for the determination of 9 organophosphate flame retardants in water samples
publisher Elsevier
publishDate 2016
url http://hdl.handle.net/10261/141196
http://dx.doi.org/10.13039/501100003329
http://dx.doi.org/10.13039/501100010805
work_keys_str_mv AT lorenzomaria ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples
AT campojulian ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples
AT picoyolanda ultrahighpressureliquidchromatographytandemmassspectrometrymethodforthedeterminationof9organophosphateflameretardantsinwatersamples
_version_ 1777665539191078912