Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus Cryoablation

Abstract Objective: The effects of energy source on the maintenance of sinus rhythm and the contribution of demographic characteristics to the case selection in patients submitted to ablation performed concurrently with mitral valve surgery were analyzed. Methods: Cryothermal (n=42; 43.8%) and radiofrequency (n=54; 56.3%) energy were employed in 96 patients submitted to mitral valve replacement and Cox maze IV procedure. Patients were called for control visits between 15 days and 12 months after discharge. The causal relationship between recurrence of atrial fibrillation and factors such as left atrial diameter, C-reactive protein, hypertension, left ventricular ejection fraction, chronic obstructive pulmonary disease, and body mass index was determined. Results: Maintenance rates of the sinus rhythm with radiofrequency and cryoablation were 97.6% and 96.3%, respectively, in the first postoperative month, whereas at the 12th postoperative month were 88.1% and 83.3%. No significant difference was found between groups in relation to the energy source. Sensitivity and specificity for left atrial diameter with a cut-off value of 50.5 mm were 85.7% and 70.7%, respectively. Sensitivity and specificity for C-reactive protein with a cut-off value of 12 mg/dL on the 15th postoperative day were 83.3% and 88.9%, respectively. The effect of body mass index on atrial fibrillation recurrence was 3.2 times. Sensitivity and specificity for left ventricular ejection fraction 37% cut-off value were 96.3% and 11.4%, respectively. Atrial fibrillation in hypertensive cases was 5.3 times more. In patients with chronic obstructive pulmonary disease, recurrence of atrial fibrillation was 40%. The causal relation between recurrence of atrial fibrillation and the studied factors was established. Conclusion: Demographic characteristics have a significant impact on ablation efficiency, while the type of energy source does not.

Saved in:
Bibliographic Details
Main Authors: Vural,Ünsal, Balcı,Ahmet Yavuz, Ağlar,Ahmet Arif, Kızılay,Mehmet
Format: Digital revista
Language:English
Published: Sociedade Brasileira de Cirurgia Cardiovascular 2018
Online Access:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382018000600542
Tags: Add Tag
No Tags, Be the first to tag this record!
id oai:scielo:S0102-76382018000600542
record_format ojs
spelling oai:scielo:S0102-763820180006005422019-07-18Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus CryoablationVural,ÜnsalBalcı,Ahmet YavuzAğlar,Ahmet ArifKızılay,Mehmet Mitral Valve/surgery Cryosurgery Catheter Ablation Ablation Ablation Techniques Abstract Objective: The effects of energy source on the maintenance of sinus rhythm and the contribution of demographic characteristics to the case selection in patients submitted to ablation performed concurrently with mitral valve surgery were analyzed. Methods: Cryothermal (n=42; 43.8%) and radiofrequency (n=54; 56.3%) energy were employed in 96 patients submitted to mitral valve replacement and Cox maze IV procedure. Patients were called for control visits between 15 days and 12 months after discharge. The causal relationship between recurrence of atrial fibrillation and factors such as left atrial diameter, C-reactive protein, hypertension, left ventricular ejection fraction, chronic obstructive pulmonary disease, and body mass index was determined. Results: Maintenance rates of the sinus rhythm with radiofrequency and cryoablation were 97.6% and 96.3%, respectively, in the first postoperative month, whereas at the 12th postoperative month were 88.1% and 83.3%. No significant difference was found between groups in relation to the energy source. Sensitivity and specificity for left atrial diameter with a cut-off value of 50.5 mm were 85.7% and 70.7%, respectively. Sensitivity and specificity for C-reactive protein with a cut-off value of 12 mg/dL on the 15th postoperative day were 83.3% and 88.9%, respectively. The effect of body mass index on atrial fibrillation recurrence was 3.2 times. Sensitivity and specificity for left ventricular ejection fraction 37% cut-off value were 96.3% and 11.4%, respectively. Atrial fibrillation in hypertensive cases was 5.3 times more. In patients with chronic obstructive pulmonary disease, recurrence of atrial fibrillation was 40%. The causal relation between recurrence of atrial fibrillation and the studied factors was established. Conclusion: Demographic characteristics have a significant impact on ablation efficiency, while the type of energy source does not.info:eu-repo/semantics/openAccessSociedade Brasileira de Cirurgia CardiovascularBrazilian Journal of Cardiovascular Surgery v.33 n.6 20182018-12-01info:eu-repo/semantics/articletext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382018000600542en10.21470/1678-9741-2018-0130
institution SCIELO
collection OJS
country Brasil
countrycode BR
component Revista
access En linea
databasecode rev-scielo-br
tag revista
region America del Sur
libraryname SciELO
language English
format Digital
author Vural,Ünsal
Balcı,Ahmet Yavuz
Ağlar,Ahmet Arif
Kızılay,Mehmet
spellingShingle Vural,Ünsal
Balcı,Ahmet Yavuz
Ağlar,Ahmet Arif
Kızılay,Mehmet
Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus Cryoablation
author_facet Vural,Ünsal
Balcı,Ahmet Yavuz
Ağlar,Ahmet Arif
Kızılay,Mehmet
author_sort Vural,Ünsal
title Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus Cryoablation
title_short Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus Cryoablation
title_full Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus Cryoablation
title_fullStr Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus Cryoablation
title_full_unstemmed Which Method to Use for Surgical Ablation of Atrial Fibrillation Performed Concomitantly with Mitral Valve Surgery: Radiofrequency Ablation versus Cryoablation
title_sort which method to use for surgical ablation of atrial fibrillation performed concomitantly with mitral valve surgery: radiofrequency ablation versus cryoablation
description Abstract Objective: The effects of energy source on the maintenance of sinus rhythm and the contribution of demographic characteristics to the case selection in patients submitted to ablation performed concurrently with mitral valve surgery were analyzed. Methods: Cryothermal (n=42; 43.8%) and radiofrequency (n=54; 56.3%) energy were employed in 96 patients submitted to mitral valve replacement and Cox maze IV procedure. Patients were called for control visits between 15 days and 12 months after discharge. The causal relationship between recurrence of atrial fibrillation and factors such as left atrial diameter, C-reactive protein, hypertension, left ventricular ejection fraction, chronic obstructive pulmonary disease, and body mass index was determined. Results: Maintenance rates of the sinus rhythm with radiofrequency and cryoablation were 97.6% and 96.3%, respectively, in the first postoperative month, whereas at the 12th postoperative month were 88.1% and 83.3%. No significant difference was found between groups in relation to the energy source. Sensitivity and specificity for left atrial diameter with a cut-off value of 50.5 mm were 85.7% and 70.7%, respectively. Sensitivity and specificity for C-reactive protein with a cut-off value of 12 mg/dL on the 15th postoperative day were 83.3% and 88.9%, respectively. The effect of body mass index on atrial fibrillation recurrence was 3.2 times. Sensitivity and specificity for left ventricular ejection fraction 37% cut-off value were 96.3% and 11.4%, respectively. Atrial fibrillation in hypertensive cases was 5.3 times more. In patients with chronic obstructive pulmonary disease, recurrence of atrial fibrillation was 40%. The causal relation between recurrence of atrial fibrillation and the studied factors was established. Conclusion: Demographic characteristics have a significant impact on ablation efficiency, while the type of energy source does not.
publisher Sociedade Brasileira de Cirurgia Cardiovascular
publishDate 2018
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-76382018000600542
work_keys_str_mv AT vuralunsal whichmethodtouseforsurgicalablationofatrialfibrillationperformedconcomitantlywithmitralvalvesurgeryradiofrequencyablationversuscryoablation
AT balcıahmetyavuz whichmethodtouseforsurgicalablationofatrialfibrillationperformedconcomitantlywithmitralvalvesurgeryradiofrequencyablationversuscryoablation
AT aglarahmetarif whichmethodtouseforsurgicalablationofatrialfibrillationperformedconcomitantlywithmitralvalvesurgeryradiofrequencyablationversuscryoablation
AT kızılaymehmet whichmethodtouseforsurgicalablationofatrialfibrillationperformedconcomitantlywithmitralvalvesurgeryradiofrequencyablationversuscryoablation
_version_ 1756429557186953216