Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat

Within the framework of a project requiring an important number of measures of lipid content in chicken breast meat, near-infrared spectrometry (NIRS) was tested in order to avoid the use of the reference extraction method requiring long analytical process. Two methods were compared: direct spectrum acquisition with a fibre optic probe on breast muscle, 24 h after slaughter and just after the cutting and boning process (spectrometer ASD, Labspec Pro) or later in the laboratory on ground breast meat (spectrometer Büchi). The direct spectral acquisition was realised on 877 fillets of broilers issued from different slaughter plants. The laboratory spectral acquisition was realised on the same 877 fillets plus 457 other samples also issued from different slaughter plants. Calibration equations established with ground meat were more precise. SECV (standard error of cross-validation) was 0.24% (R2=0.83) for lipids, which is equivalent to the repeatability of reference measurements (0.20%). The direct measurements on breast muscle led to a less precise calibration equation (lipids: SECV=0.37%, R2=0.68). In conclusion, the prediction of lipid content with NIRS provided satisfactory data when spectra were realized in the laboratory on ground breast meat. Direct measurement was less precise, but allowed a useful in situ estimation of the chemical composition.

Saved in:
Bibliographic Details
Main Authors: Chartrin, Pascal, Rousseau, X., Gigaud, V., Bastianelli, Denis, Baéza, Elisabeth
Format: conference_item biblioteca
Language:eng
Published: s.n.
Subjects:U30 - Méthodes de recherche, Q04 - Composition des produits alimentaires, L50 - Physiologie et biochimie animales,
Online Access:http://agritrop.cirad.fr/556553/
http://agritrop.cirad.fr/556553/1/document_556553.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
id dig-cirad-fr-556553
record_format koha
spelling dig-cirad-fr-5565532022-03-30T12:56:07Z http://agritrop.cirad.fr/556553/ http://agritrop.cirad.fr/556553/ Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat. Chartrin Pascal, Rousseau X., Gigaud V., Bastianelli Denis, Baéza Elisabeth. 2010. In : XIIIth European Poultry Conference, 23-27 août 2010, Tours, France. s.l. : s.n., 5 p. European Poultry Conference. 13, Tours, France, 23 Août 2010/27 Août 2010. Researchers Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat Chartrin, Pascal Rousseau, X. Gigaud, V. Bastianelli, Denis Baéza, Elisabeth eng 2010 s.n. XIIIth European Poultry Conference, 23-27 août 2010, Tours, France U30 - Méthodes de recherche Q04 - Composition des produits alimentaires L50 - Physiologie et biochimie animales Within the framework of a project requiring an important number of measures of lipid content in chicken breast meat, near-infrared spectrometry (NIRS) was tested in order to avoid the use of the reference extraction method requiring long analytical process. Two methods were compared: direct spectrum acquisition with a fibre optic probe on breast muscle, 24 h after slaughter and just after the cutting and boning process (spectrometer ASD, Labspec Pro) or later in the laboratory on ground breast meat (spectrometer Büchi). The direct spectral acquisition was realised on 877 fillets of broilers issued from different slaughter plants. The laboratory spectral acquisition was realised on the same 877 fillets plus 457 other samples also issued from different slaughter plants. Calibration equations established with ground meat were more precise. SECV (standard error of cross-validation) was 0.24% (R2=0.83) for lipids, which is equivalent to the repeatability of reference measurements (0.20%). The direct measurements on breast muscle led to a less precise calibration equation (lipids: SECV=0.37%, R2=0.68). In conclusion, the prediction of lipid content with NIRS provided satisfactory data when spectra were realized in the laboratory on ground breast meat. Direct measurement was less precise, but allowed a useful in situ estimation of the chemical composition. conference_item info:eu-repo/semantics/conferenceObject Conference info:eu-repo/semantics/publishedVersion http://agritrop.cirad.fr/556553/1/document_556553.pdf application/pdf Cirad license info:eu-repo/semantics/openAccess https://agritrop.cirad.fr/mention_legale.html http://catalogue-bibliotheques.cirad.fr/cgi-bin/koha/opac-detail.pl?biblionumber=208746
institution CIRAD FR
collection DSpace
country Francia
countrycode FR
component Bibliográfico
access En linea
databasecode dig-cirad-fr
tag biblioteca
region Europa del Oeste
libraryname Biblioteca del CIRAD Francia
language eng
topic U30 - Méthodes de recherche
Q04 - Composition des produits alimentaires
L50 - Physiologie et biochimie animales
U30 - Méthodes de recherche
Q04 - Composition des produits alimentaires
L50 - Physiologie et biochimie animales
spellingShingle U30 - Méthodes de recherche
Q04 - Composition des produits alimentaires
L50 - Physiologie et biochimie animales
U30 - Méthodes de recherche
Q04 - Composition des produits alimentaires
L50 - Physiologie et biochimie animales
Chartrin, Pascal
Rousseau, X.
Gigaud, V.
Bastianelli, Denis
Baéza, Elisabeth
Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
description Within the framework of a project requiring an important number of measures of lipid content in chicken breast meat, near-infrared spectrometry (NIRS) was tested in order to avoid the use of the reference extraction method requiring long analytical process. Two methods were compared: direct spectrum acquisition with a fibre optic probe on breast muscle, 24 h after slaughter and just after the cutting and boning process (spectrometer ASD, Labspec Pro) or later in the laboratory on ground breast meat (spectrometer Büchi). The direct spectral acquisition was realised on 877 fillets of broilers issued from different slaughter plants. The laboratory spectral acquisition was realised on the same 877 fillets plus 457 other samples also issued from different slaughter plants. Calibration equations established with ground meat were more precise. SECV (standard error of cross-validation) was 0.24% (R2=0.83) for lipids, which is equivalent to the repeatability of reference measurements (0.20%). The direct measurements on breast muscle led to a less precise calibration equation (lipids: SECV=0.37%, R2=0.68). In conclusion, the prediction of lipid content with NIRS provided satisfactory data when spectra were realized in the laboratory on ground breast meat. Direct measurement was less precise, but allowed a useful in situ estimation of the chemical composition.
format conference_item
topic_facet U30 - Méthodes de recherche
Q04 - Composition des produits alimentaires
L50 - Physiologie et biochimie animales
author Chartrin, Pascal
Rousseau, X.
Gigaud, V.
Bastianelli, Denis
Baéza, Elisabeth
author_facet Chartrin, Pascal
Rousseau, X.
Gigaud, V.
Bastianelli, Denis
Baéza, Elisabeth
author_sort Chartrin, Pascal
title Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
title_short Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
title_full Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
title_fullStr Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
title_full_unstemmed Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
title_sort near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
publisher s.n.
url http://agritrop.cirad.fr/556553/
http://agritrop.cirad.fr/556553/1/document_556553.pdf
work_keys_str_mv AT chartrinpascal nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat
AT rousseaux nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat
AT gigaudv nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat
AT bastianellidenis nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat
AT baezaelisabeth nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat
_version_ 1758022591909462016