Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat
Within the framework of a project requiring an important number of measures of lipid content in chicken breast meat, near-infrared spectrometry (NIRS) was tested in order to avoid the use of the reference extraction method requiring long analytical process. Two methods were compared: direct spectrum acquisition with a fibre optic probe on breast muscle, 24 h after slaughter and just after the cutting and boning process (spectrometer ASD, Labspec Pro) or later in the laboratory on ground breast meat (spectrometer Büchi). The direct spectral acquisition was realised on 877 fillets of broilers issued from different slaughter plants. The laboratory spectral acquisition was realised on the same 877 fillets plus 457 other samples also issued from different slaughter plants. Calibration equations established with ground meat were more precise. SECV (standard error of cross-validation) was 0.24% (R2=0.83) for lipids, which is equivalent to the repeatability of reference measurements (0.20%). The direct measurements on breast muscle led to a less precise calibration equation (lipids: SECV=0.37%, R2=0.68). In conclusion, the prediction of lipid content with NIRS provided satisfactory data when spectra were realized in the laboratory on ground breast meat. Direct measurement was less precise, but allowed a useful in situ estimation of the chemical composition.
Main Authors: | , , , , |
---|---|
Format: | conference_item biblioteca |
Language: | eng |
Published: |
s.n.
|
Subjects: | U30 - Méthodes de recherche, Q04 - Composition des produits alimentaires, L50 - Physiologie et biochimie animales, |
Online Access: | http://agritrop.cirad.fr/556553/ http://agritrop.cirad.fr/556553/1/document_556553.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
id |
dig-cirad-fr-556553 |
---|---|
record_format |
koha |
spelling |
dig-cirad-fr-5565532022-03-30T12:56:07Z http://agritrop.cirad.fr/556553/ http://agritrop.cirad.fr/556553/ Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat. Chartrin Pascal, Rousseau X., Gigaud V., Bastianelli Denis, Baéza Elisabeth. 2010. In : XIIIth European Poultry Conference, 23-27 août 2010, Tours, France. s.l. : s.n., 5 p. European Poultry Conference. 13, Tours, France, 23 Août 2010/27 Août 2010. Researchers Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat Chartrin, Pascal Rousseau, X. Gigaud, V. Bastianelli, Denis Baéza, Elisabeth eng 2010 s.n. XIIIth European Poultry Conference, 23-27 août 2010, Tours, France U30 - Méthodes de recherche Q04 - Composition des produits alimentaires L50 - Physiologie et biochimie animales Within the framework of a project requiring an important number of measures of lipid content in chicken breast meat, near-infrared spectrometry (NIRS) was tested in order to avoid the use of the reference extraction method requiring long analytical process. Two methods were compared: direct spectrum acquisition with a fibre optic probe on breast muscle, 24 h after slaughter and just after the cutting and boning process (spectrometer ASD, Labspec Pro) or later in the laboratory on ground breast meat (spectrometer Büchi). The direct spectral acquisition was realised on 877 fillets of broilers issued from different slaughter plants. The laboratory spectral acquisition was realised on the same 877 fillets plus 457 other samples also issued from different slaughter plants. Calibration equations established with ground meat were more precise. SECV (standard error of cross-validation) was 0.24% (R2=0.83) for lipids, which is equivalent to the repeatability of reference measurements (0.20%). The direct measurements on breast muscle led to a less precise calibration equation (lipids: SECV=0.37%, R2=0.68). In conclusion, the prediction of lipid content with NIRS provided satisfactory data when spectra were realized in the laboratory on ground breast meat. Direct measurement was less precise, but allowed a useful in situ estimation of the chemical composition. conference_item info:eu-repo/semantics/conferenceObject Conference info:eu-repo/semantics/publishedVersion http://agritrop.cirad.fr/556553/1/document_556553.pdf application/pdf Cirad license info:eu-repo/semantics/openAccess https://agritrop.cirad.fr/mention_legale.html http://catalogue-bibliotheques.cirad.fr/cgi-bin/koha/opac-detail.pl?biblionumber=208746 |
institution |
CIRAD FR |
collection |
DSpace |
country |
Francia |
countrycode |
FR |
component |
Bibliográfico |
access |
En linea |
databasecode |
dig-cirad-fr |
tag |
biblioteca |
region |
Europa del Oeste |
libraryname |
Biblioteca del CIRAD Francia |
language |
eng |
topic |
U30 - Méthodes de recherche Q04 - Composition des produits alimentaires L50 - Physiologie et biochimie animales U30 - Méthodes de recherche Q04 - Composition des produits alimentaires L50 - Physiologie et biochimie animales |
spellingShingle |
U30 - Méthodes de recherche Q04 - Composition des produits alimentaires L50 - Physiologie et biochimie animales U30 - Méthodes de recherche Q04 - Composition des produits alimentaires L50 - Physiologie et biochimie animales Chartrin, Pascal Rousseau, X. Gigaud, V. Bastianelli, Denis Baéza, Elisabeth Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat |
description |
Within the framework of a project requiring an important number of measures of lipid content in chicken breast meat, near-infrared spectrometry (NIRS) was tested in order to avoid the use of the reference extraction method requiring long analytical process. Two methods were compared: direct spectrum acquisition with a fibre optic probe on breast muscle, 24 h after slaughter and just after the cutting and boning process (spectrometer ASD, Labspec Pro) or later in the laboratory on ground breast meat (spectrometer Büchi). The direct spectral acquisition was realised on 877 fillets of broilers issued from different slaughter plants. The laboratory spectral acquisition was realised on the same 877 fillets plus 457 other samples also issued from different slaughter plants. Calibration equations established with ground meat were more precise. SECV (standard error of cross-validation) was 0.24% (R2=0.83) for lipids, which is equivalent to the repeatability of reference measurements (0.20%). The direct measurements on breast muscle led to a less precise calibration equation (lipids: SECV=0.37%, R2=0.68). In conclusion, the prediction of lipid content with NIRS provided satisfactory data when spectra were realized in the laboratory on ground breast meat. Direct measurement was less precise, but allowed a useful in situ estimation of the chemical composition. |
format |
conference_item |
topic_facet |
U30 - Méthodes de recherche Q04 - Composition des produits alimentaires L50 - Physiologie et biochimie animales |
author |
Chartrin, Pascal Rousseau, X. Gigaud, V. Bastianelli, Denis Baéza, Elisabeth |
author_facet |
Chartrin, Pascal Rousseau, X. Gigaud, V. Bastianelli, Denis Baéza, Elisabeth |
author_sort |
Chartrin, Pascal |
title |
Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat |
title_short |
Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat |
title_full |
Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat |
title_fullStr |
Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat |
title_full_unstemmed |
Near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat |
title_sort |
near-infrared reflectance spectroscopy for predicting lipid content in chicken breast meat |
publisher |
s.n. |
url |
http://agritrop.cirad.fr/556553/ http://agritrop.cirad.fr/556553/1/document_556553.pdf |
work_keys_str_mv |
AT chartrinpascal nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat AT rousseaux nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat AT gigaudv nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat AT bastianellidenis nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat AT baezaelisabeth nearinfraredreflectancespectroscopyforpredictinglipidcontentinchickenbreastmeat |
_version_ |
1758022591909462016 |